58
Approve the entered text with the "
key
" button. The changes are stored in
memory. The module display shows “saving data, please wait”. Sorting by
alphabet is only possible with a PC program. If alphabetical sorting is enabled, it
is not possible to add or edit individual names on the unit. Pressing the "#" key
at any time (except when saving the data) exits the program without saving the
changes.
The CDN -230E module does not show the entry if ringing is called from other
modules such as: I/O, 2NP, 6NP, 10NP or additional panel input. Refer to
chapter XV for memory deletion.
P20 PROGRAMMING THE ACC OPENING MODULE
M-ACC
This program is used to add proximity cards and key fobs to ACC module.
Supported cards and key fobs are in the Unique 125 kHz standard.
For each uniphone physical address (from 1 to 255) up to 6 cards or key fobs can
be assigned (with sequence numbers from 1 to 6). It is possible to add 6 additional
Admin cards that are not assigned to any uniphone physical address.
The card (key fobs), which has been added to the module memory, becomes
active and when it is used, it starts the opening procedure in the unit (E-lock
activation). If the door opening signal is enabled in P4, the confirmation of opening
procedure will be heard in the uniphone for the address to which the card is
assigned.
Adding and removing cards:
After entering the program, "
Adres?
" will be displayed - the unit waits for the value
to be entered from the range 1 to 255, which corresponds to the uniphone physical
address to which the card (cards) is to be assigned. Entered 1-digit and 2-digit
values must be confirmed by pressing the "
key
" button, while a 3-digit value is
saved by the unit automatically without confirmation.
Entering "
0
" will add an Admin card to the module.
Adding cards individually:
When the value "
Adres?
" is entered, the display will show "
Card
”. Then press the
unit button 1 to 6 corresponding to the sequence number (position) for which the
card is to be assigned, and then move the new card close to the module. If a card
has already been recorded before or another card has already been recorded in
that position, the display will show "
Error!
" and the unit will terminate the
programming by exiting the program. When the card is added correctly, "
Ready
"
will appear on the display.