33
P1 MODIFICATION OF USER’S ACCESS CODE (RESIDENT’S OR
ADMINISTRATOR’S CODE)
PIN
The code can be used to activate E-lock (for instance to open the front door) or
to activate another device connected to the ELOCK output (for instance via the
CDN-
PK relay module); it can also be used, upon pressing the “key” button twice,
to activate the relay output of the CDN-I/O module (for instance to open gate 2) -
P18 program.
1.-
Modification of user’s access code
Changing the code of apartment 9 to 4256:
Upon entering the program the text "
Nbr ?
" [number] is displayed, now enter 9 as
the apartment number, confirm with the "
key
" button, the current code will be
displayed for a brief moment (to exit the function without changing the code, press
the "#" button now), and then the text "
Digit1
" will appear, now enter the first digit
of the code - "4", ("
Digit2
") the second digit -
"2", (“
Digit3
") the third digit - "5",
(“
Digit4
"), and the last, fourth digit - "6". "
Done
" will be displayed and code 4256
for apartment 9 will be stored in unit’s memory.
Now the value “
Nbr ?
” is the new call number, to be selected with the keypad,
since the unit operates as per the settings in P9 (offset, range) and automatically
calculates the uniphone physical address. Please note that the access codes in
the
Code Table
, supplied with the unit as a standard, correspond to physical
addresses set in the uniphone, which is important when offsets are pre-set.
After restoring the factory settings of the unit, also factory codes described in the
table are restored.
Access codes may also be changed by residents - refer to description in the P16
program, bit7.
To lock the access codes completely, set the "9999” code table.
2.-
Modification of administrator’s access code
Enter the program, wait for "
Nbr ?
” to be displayed, then enter 0 as apartment
number and confirm with the "
key
” button ("
KodAdm
" will be displayed briefly).
When "
Digit1
" is displayed, enter the first digit of the code, with "
Digit2
" enter the
second digit, and so on. Upon entering the last digit, the unit will display "
Redy
";
the code is now stored in unit’s memory as administrator’s code. The new code
will erase the previous code value. The code is also erased when the unit is reset
to factory default settings. Do not enter a code that starts with 1507, as these are
the initial digits of the installer's password (the unit will display "
Error!
" and the
unit will exit the programming mode).
The E-lock is activated by selecting the "
key
" button and entering the six digits (or
the first
four if bit2 in P17 is enabled) of the administrator’s code. The
administrator’s code is not pre-set.