53
Set the following parameters in the program:
-
“
IN
”:
enter value 0 to 255 for input of the first or second port (
“
IN1
” or “
IN2
”
)
-
“
OU
”:
enter output activity time in seconds from 0 do 255 of the first or
second port (
“
OU1
” or “
OU2
””
)
-
“
Nrf
”:
enter function number 0 to 3 that is to be assigned to the first or
second port (
“
Nrf1
” or “
Nrf2
”
)
If the port output activity time is set to zero and "0" is set for this port, the entire
port will be inactive (input and output) - default setting.
It is not possible to control output1 with input2 and vice versa.
Description of the input parameters:
If any function (
“
Nrf
“
) other than zero (1 to 3) is set, shorting the input of this
port to GND will cause the following action:
- for parameter
“
IN
“
= 0 - the E-lock is activated,
- for parameter
“
IN
“
= 1 to 255 - the uniphone with this physical address is
called.
For proper operation of the inputs, the duration of the port output activity
(
“
OU
“
) is irrelevant.
CDNP6 only:
It is possible to activate the E-lock without connecting to the
uniphone (and without connecting an I/O module).
Then set the P1 port as follows:
- port output activity time to 0 -
“
OU1
”
= 0,
- port input activity time to 0 -
“
IN1
”
= 0,
- port function 3 -
“
Nrf1
”
= 3,
With this setting, the E-lock is activated after pressing the open button on the
uniphone three times (with the handset lifted).
Description of the output parameters:
For each output (
“
OU
”
parameter) its activation (action) time in seconds within
the range from 1 to 255 can be set. When the entered time is "0" the output is
inactive - disabled. For each output (
“
Nrf
”
parameter) the number of the
function from 0 to 3 that it is to perform can be set, as described below:
Function No. 0:
The output will be activated for a pre-set time when each input of
this port is shorted to ground. Such setting can be used for control of opening
of an additional entrance gate (using the third wire from F2 button of the INS-
UP720M uniphone), etc.
Function No. 1
: The output will be activated for a pre-set time before each E-lock
activation; it can be used, for example, to connect a reversible E-lock or to
control the lights in a staircase.
Содержание CDNP6ACC
Страница 67: ...67 Notes...
Страница 68: ...68 IU0401envJ 2247 62 002 Suchy Las ul Diamentowa 7 tel fax 61 843 93 72 www aco com pl...