41
Then apartments with number above this number cannot be opened with an
access code and "
Error!
" will appear on the display. When the call number
offset is pre-set,
the “
From
" and “
To
" parameters are entered as actual call
numbers (dialled from keypad), rather than the number physically set on the
uniphone board.
Setting these parameters is necessary for proper operation of the slave unit
when working with the master unit.
P10 HOTEL SYSTEM DIALLING SETTINGS
Hotel
P10 can be used to set all parameters for Hotel Mode, which is described in
chapter X.
Hotel mode programming is usually performed in all units, which support main
entrances to the facility (from which each apartment must be called).
When the unit is in the Hotel mode, it supports the so called "Zones". A zone can
be, for example, a staircase, a building, a complex of buildings, etc. Each zone
can be freely configured by setting its range of supported uniphones and offset.
Hence the system can be configured in such a way that the subscriber numbers
in the zones may be repeated - the ranges and offsets are set in the zones in such
a way as not to exceed the maximum number of 255 uniphones, keeping the rule
that each zone can have maximum 99 uniphones and the physical addresses of
uniphones cannot be repeated throughout the system.
Any number of slave units can work in each zone in which the hotel system is no
longer used; instead the range and offset are set in a conventional way in P9 (in
this case also the positive offset is used - by setting bit6 in P16). The following
figure provides a better understanding of how the hotel system works.