ACO offers off-the-shelf CDN-PK modules. 

 

 

Relay  contacts  can  be  used  as  needed  -  it  is  recommended  to  power  the  unit 
connected to relay contacts from a separate power supply. Do not connect other 
inductive  loads  (such  as  an  E-lock)  via  a  relay  from  the  same  transformer  that 
powers the door entry unit. 

 

 

5. Connection of the receivers (wiring - topology):

 

Refer to chapter V for details on receiver wiring. 
Passive audio receivers (2-wire) are wired using a 2-wire intercom cable, and the 
terminals of all receivers are connected in parallel and connected to the "

LINE

terminals  of  the  door  entry  unit.  Make  sure  that 

terminals  of  the  receiver  are 

properly connected to 

LINE+ 

of the door entry unit and 

-

 terminals of the receiver 

properly  connected  to 

LINE  -

  the  door  entry  unit.  Improper  wiring  of  even  one 

receiver will cause bad operation of the entire system. 
Same with active audio receivers that need two additional wires for power supply. 
All power and LINE terminals of the receivers are to be connected in parallel. In 
small systems one power supply will support both the receiver and the door entry 
unit  -  in  each  case  a  DC  power  supply.  For  larger  installations  that  require 
additional  power  supplies  for  receivers,  LINE  and  -DC  (GND)  terminals  of  all 
receivers  should  always  be  connected  in  parallel  then  connected  to  door  entry 
unit, and the +DC to -DC terminals for additional power supplies. 

 

 

For  Video  systems,  the  entire  wiring  must  be  made  using  UTPs  in  T568B 
standard, min. cat 5e standard (all wires to be used); these systems also require 
optional  combiner  modules:  for  Master  devices: 

CDNVS

,  for  Slave  devices: 

CDNVSp.

 

Note! 

All UTPs should be ended with an RJ-45 plug, making sure that the same 

wire sequence is maintained. 
UTP should origin at the door  entry unit (combiner output), to the main input of 
the first splitter, then the main output of the splitter is to be connected to the main 
input of the next splitter and so on. The last splitter must be a terminal splitter or 
a video terminator jumper. 
All splitter in video systems must be active and the monitors are to be connected 
using  relevant  outputs  of  the  splitter.  Monitors  on  cat  5e  UTPs  should  be 
connected at a distance of 70m or less from the connection point, while the whole 
system must remain within 300 m. Additional power supplies can be connected 
directly to the splitters - then the right jumper in specific splitter must be removed. 
Another way to wire the installation is to keep all active splitters in one place and 
branch to each monitor. 

Содержание CDNP6ACC

Страница 1: ...EXTENDED USER INSTRUCTION FOR THE CDNP5 CDNP6 CDNP6ACC DIGITAL DOOR ENTRY SYSTEM ACO Sp z o o sp komandytowa 62 002 Suchy Las ul Diamentowa 7 phone fax 48 790 709 062 www aco com pl...

Страница 2: ...THE AUXILIARY INPUT 44 P13 SETTING ONE OF FOUR RINGTONES 45 P14 SEARCHING MISPLACED OR DEFECTIVE UNIPHONES 46 P15 ADDITIONALLY SUPPORTED NUMBERS 46 P16 BITY 1 UNIT PARAMETER SETTINGS 48 Bit1 Enable f...

Страница 3: ...entry unit with digital dialling as well as apartment number display and access control function front door code opening It features a large blue backlit LCD display and a blue backlit keyboard A spe...

Страница 4: ...y key reader the CDNP6ACC version The control unit can also support control of an additional gate etc from uniphone button F2 by means of individual resident codes or proximity cards key fobs for CDNP...

Страница 5: ...elay module to connect another device in place of the E lock It is also possible to use one door entry unit to control two pairs of doors to open the right apartment door CDN I O module required Apart...

Страница 6: ...subscriber their number must be selected using the keypad the number will appear on the display Within 3 seconds the uniphone in the apartment will start ringing First the unit sends ringing tones as...

Страница 7: ...onal gate etc The unit features an output for direct connection of a standard E lock or reversible E lock in case of CDNP6 Use CDN PK relay module to connect another device in place of the E lock The...

Страница 8: ...not programmed will generate a beep sound twice 4 With administrator s access code To get access using the administrator s code press the key button on the keypad and then enter the six digit adminis...

Страница 9: ...fer to the P6 and P16 program description bit 1 and bit4 By default this function is disabled 8 Input from additional module For this unit door opening is also possible via an additional module such a...

Страница 10: ...imity reader the second output can also be activated without pressing the key button and the proximity card or proximity key fob resident s or administrator installer s The unit detects a short circui...

Страница 11: ...le operates at radio frequency and is used for door opening with a card or key fob It supports 6 cards or key fobs for each apartment plus 6 additional cards or key fobs hence a maximum of 1530 cards...

Страница 12: ...side by side or one above the other The module needs to be connected to the EXTMOD1 or EXTMOD2 auxiliary input of the unit and the numbers are programmed directly from the keypad in the M xNP P21 prog...

Страница 13: ...name list app 15 in total The backlight is powered by 12VAC unit terminals 12VAC or 15VDC DC unit terminals DC ELOCK and GND LINE 2NP module 2 buttons window It is used to call selected apartments dir...

Страница 14: ...g module with opening function This module can be used to connect additional devices signalling ringing in the apartment for instance additional bells light bulbs etc for persons with hearing impairme...

Страница 15: ...es as permission to connect the call If voltage drop below 5V other then during a connection or a call is recognised as a short circuit by the unit the display shows LineEr The line is then de energis...

Страница 16: ...crews of the housing to the frame using a 3mm Allen wrench CONNECTIONS Connect the following wires to the unit 2 wires x 1mm2 power supply to the transformer for the Audio system or power supply for t...

Страница 17: ...necting the grounding terminal on unit s body with relevant protective installation PE For wires of other cross sections use the following formula to calculate the voltage drop 2 x L m x I A U V 57 x...

Страница 18: ...so possible to connect a reversible E lock opens when de energised This option can be activated by in the installer s menu No P10 and upon closing the Z13 jumper if presnet In this case ELOCK is energ...

Страница 19: ...tions that require additional power supplies for receivers LINE and DC GND terminals of all receivers should always be connected in parallel then connected to door entry unit and the DC to DC terminal...

Страница 20: ...ll at the same time have the same address this must be taken into consideration when selecting the number of power supplies assume one 15VDC 2 8A power supply per 6 monitors calling at the same Combin...

Страница 21: ...21 WIRING DIAGRAM INSTALLATION WITH ONE UNIT Installation with one unit is wired as shown below All connections in the installation must be soldered CDNP6 only...

Страница 22: ...ON ON ON ON ON ON ON ON ON ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 1 white amber 2 amber 3 white green 4 blue 5 white blue 6 green 7 white brown 8 brown Act splitter Przel 4 wy Remove j...

Страница 23: ...per Chapter VIII of this manual PLEASE NOTE When setting up the unit uniphone connection unwanted acoustic signals may occur the level of which does not distort the content of the transmitted message...

Страница 24: ...its is similar to the way of handling individual units the CDNP5 series units must have bit 2 in the P16 switched on in order to ensure proper operation of the system to be used as a master unit in th...

Страница 25: ...ation of further door opening in master units In factory settings the further door opening function is disabled A system in which multiple units are installed will operate correctly only if the number...

Страница 26: ...s of the line of the upstream unit the minus of the main line is connected to the LINE terminal Refer to the wiring diagram on the next page Each panel must be powered from a separate transformer For...

Страница 27: ...e first two e g different entrance to the building entrance to a staircase entrance to a floor etc E lock max 1A Power supply for the panel Power supply for the panel Slave unit e g Entrance 1 to Buil...

Страница 28: ...o Line No Unit Camera P sup Li ne Vi de o Out In Intermediate combiner Auxiliary input EXTMOD connector Unit terminals Unit terminals Unit Camera P sup Li ne Li ne Vi de o Out Combiner Remove jumper a...

Страница 29: ...ter unit The installer code as well as other settings may be individual in each unit for instance door opening time depending on the location in relation to the unit ringing tone to identify the unit...

Страница 30: ...n the number dialled on the keypad and the physical address set in the device This is set in P10 program which can be accessed when the hotel function is activated bit 5 in P16 Additionally in all uni...

Страница 31: ...e unit are saved in permanent memory and are not lost when the power is turned off For systems with multiple units modifications to the settings apply only to the unit in which they were made To trans...

Страница 32: ...nit will automatically exit the installer programming without changing any setting values Exit from the installer function is possible by pressing the key through the 0 function with lock opening or a...

Страница 33: ...cal address Please note that the access codes in the Code Table supplied with the unit as a standard correspond to physical addresses set in the uniphone which is important when offsets are pre set Af...

Страница 34: ...with different phones P3 SETTING THE NUMBER OF RINGTONES PERMISSION TO CALL Rings This program is used to change the number of ringtones between 1 and 7 for the main ringing to apartments Entering 0 w...

Страница 35: ...e code card is assigned Program P4 can be used to disable or enable this signal By default the signal is enabled Enter the program wait for Nbr to be displayed then enter the number of the apartment f...

Страница 36: ...the From To range set in P9 the function is active for approx 4 5 hours The key button will confirm the entered digit the button will exit the program When this function is active normal operation of...

Страница 37: ...its as a delay time for the further door opening function This is the time during which pressing the key button on the slave unit the E lock released This delay is activated when the E lock is activat...

Страница 38: ...set the password to 1507 0000 the unit settings must be erased which means that all previously changed settings are lost P8 VERIFYING CARD ASSIGNMENT TO APARTMENTS Fobs The program is used verify pro...

Страница 39: ...is displayed a new parameter value can be entered 1 to 998 or the key button pressed to move to the next parameter without changing this value When the parameters have been saved correctly Ready will...

Страница 40: ...alling 114 the apartment with the uniphone physical number set to 114 will be called which is apartment 14 in staircase 1 Hence when dialling 219 apartment 19 in staircase 2 will be called The offset...

Страница 41: ...unit is in the Hotel mode it supports the so called Zones A zone can be for example a staircase a building a complex of buildings etc Each zone can be freely configured by setting its range of support...

Страница 42: ...l mode bit5 in P16 is enabled and it is also necessary to enable the positive offset bit6 in P16 is must be enables when the unit is in the Hotel mode settings in the P9 program cannot be changed and...

Страница 43: ...are to be changed from 1 to 9 or 0 for zone 10 and confirm with the key button The From parameter will be displayed enter the value of the first uniphone number in a zone from the range 1 to 99 and c...

Страница 44: ...Gotowe will be displayed When this operation is completed the access codes assigned to apartments will change to those in the new table The installer password remains unchanged change it in P7 The cod...

Страница 45: ...f four ringtones for each apartment individually or for all apartments at the same time The ringtone is set separately for each unit so different ringtones can be set in different units this way the r...

Страница 46: ...uniphone is found the unit will signal by a sound signal blinking of the display backlight and displaying its number When the key button is pressed the unit starts searching other uniphones The searc...

Страница 47: ...ority and calling in these cases is always made according to their settings The access code of an active additional number is the code of its physical address Set the following parameters in the progr...

Страница 48: ...ext parameters displayed are Lid number of ringtones value 1 7 HiLo volume level value 1 or 2 and finally AOpn automatic opening values 1 on or 0 off When the parameters have been saved correctly Read...

Страница 49: ...activates a function that is intended after the door opening procedure at the panel to send a pulse that causes the further door opening function to be activated in downstream units Waiting for door...

Страница 50: ...it will display Error and will exit the function without changing the code To exit new code programming without changing the code press the button Bit8 Disabling factory settings reset 8Rst This bit c...

Страница 51: ...s Bit2 Abbreviated four digit administrator s access code 24Key When this bit is enabled the six digit administrator s access code programmed in P1 is abbreviated to the first four digits Bit3 Doorman...

Страница 52: ...k activation calling the opening procedure apartment calling The outputs of both ports can be used independently output activation for a pre set time after setting the input of the same port output ac...

Страница 53: ...tivate the E lock without connecting to the uniphone and without connecting an I O module Then set the P1 port as follows port output activity time to 0 OU1 0 port input activity time to 0 IN1 0 port...

Страница 54: ...with a proximity card involves pressing the key button and then using the card on the ACC reader This function can be used to open the entrance gate no additional wires are required for the installati...

Страница 55: ...ters but for the second port IN2 OU2 Nrf2 When the parameters have been saved correctly Ready will appear on the display Detailed description of individual functions and example of CDN I O module appl...

Страница 56: ...rF 3 Works only for P2 port Example of the CDN I O module settings Example settings Settings Remar ks Opening the second gate using the code double key using the F2 button on the uniphone and CDNP6 on...

Страница 57: ...and the software can be downloaded free of charge from www aco com pl When the Adres value is entered H H will appear on the panel screen and the data assigned to that address will appear on the modu...

Страница 58: ...e memory becomes active and when it is used it starts the opening procedure in the unit E lock activation If the door opening signal is enabled in P4 the confirmation of opening procedure will be hear...

Страница 59: ...t the CDN ACC module to a PC using the special CDN USB cable and download the software free of charge from www aco com pl Time of card entering is limited to about 10s It is possible to check the corr...

Страница 60: ...ng space Approve the entered text with the key button to store it in the memory Pressing the key exits the program without saving the changes The unit can store 6 different screens 6 characters each w...

Страница 61: ...lock If on the other hand ringing or opening with card code is done outside the From TO range the port1 relay does not switch applying voltage to the other E lock In the settings of the I O module pro...

Страница 62: ...the same time when switching on the unit after the countdown stops while ACO is displayed briefly Pressing the 123 buttons simultaneously will restore the first language XIV INSTALLING THE BUTTON FOR...

Страница 63: ...tion deletes all data and enters the main screen intro module with manufacturer data If it is necessary to sort the entries alphabetically connect the module to a PC and use the 230E software 4 Deleti...

Страница 64: ...OR INSTALLATION AND USE Installation should be carried out by a qualified installer Before opening the unit casing turn off the power supply Avoid unstable power sources and electrical surges as this...

Страница 65: ...12VAC Each unit in the system must feature a separate transformer Door opening signalled by the unit but E lock won t work Check E lock or E lock connection to the unit Check whether or not the supply...

Страница 66: ...he further door opening pulse CDNP5 only Version 5 50 K 00 to K 02 Adding support for the Multimaster module CDN MM Minor bug fixes Version 5 50 K 02 to K 07 Minor bug fixes Version 5 50 K 08 Minor bu...

Страница 67: ...67 Notes...

Страница 68: ...68 IU0401envJ 2247 62 002 Suchy Las ul Diamentowa 7 tel fax 61 843 93 72 www aco com pl...

Отзывы: