50
Used to dial apartments with a number higher than 255.
-
“
Adding
”
:
bit enabled - "1". In this setting, the unit adds the value of the offset
set in P9 from the apartment number selected on the keypad and makes a call
to the uniphone with physical address resulting from this sum. Adding is mostly
used in slave units, working with a unit set to hotel mode.
Bit7.- Enabling access code change by the user [7Chng]
When this bit is enabled, users may change their unique access codes. Access
code change procedure:
After calling the conventional opening procedure (selecting the apartment
number, confirming with the "
key
" button and selecting the old access code),
press the "
key
" button again during the first 2 seconds of the opening procedure
-
"
PIN
" and "
Digit1
" will appear. Now enter four digits of the new access code.
When "
Again
" is displayed, enter the new access code again (to avoid errors). If
both entries are the same, the unit will display "
Ready
"; the new code is now
stored in unit’s memory. If entries are different, the unit will display "
Error!
" and
will exit the function without changing the code. To exit new code programming
(without changing the code) press the "#" button.
Bit8.- Disabling factory settings reset [8Rst]
This bit can be used to enable or disable factory settings restore of the unit
(clearing the unit memory settings). When the bit is enabled ("1"), upon turning on
the unit and when the countdown is completed (when the unit displays "
ACO
”
briefly), pressing "2,5,8" at the same time will initiate the factory settings restore
procedure. When the bit is disabled ("0") factory settings restore is not possible.By
default, factory settings restore is enabled - "1".
PLEASE NOTE! If factory settings restore is disabled and the installer
password is unknown, it is not possible to enter the installation procedures.
Then only the manufacturer may restore the default installer’s password.
In the factory settings, all bits except bit3 and bit8 are disabled.
P17 BITY-2 UNIT PARAMETER SETTINGS
Bits2
This program is used to set bit parameters for unit operation, which can be only
switched on - value "1" or off - value "0".
After entering the program by pressing the "
key
" button the current settings of
subsequent bits can be reviewed (without changes).
Содержание CDNP6ACC
Страница 67: ...67 Notes...
Страница 68: ...68 IU0401envJ 2247 62 002 Suchy Las ul Diamentowa 7 tel fax 61 843 93 72 www aco com pl...