61
Any higher value will disable this function. "0” will cause immediate display of the
message.
The time entered should be considered as a guide - after a year the difference
may be even a few days. Any power failure periods are excluded from the time
countdown. By default this function is disabled. After disable the factory settings
restore of the unit (bit 8 in P16), the message can only be switched off using the
installer’s password.
P24 PROGRAMMING ADDITIONAL
“OD-DO” [from-to] RANGE
Range
This program is used to set the range of additional uniphone addresses, which is
associated with the use of
function 1 of port 1
in the I/O module. This function
can be used for opening one of two pairs of doors on the unit, depending on the
selected apartment address (one of two E-locks is activated). This may occur
when the estate features two gates and only one unit can be installed. This
function is also effective when using card or code opening for an apartment.
If ringing or opening with card/code is done within the set "
From-TO
" range, the
port1
relay switches by applying voltage to one E-lock. If, on the other hand,
ringing or opening with card/code is done outside the "
From-TO
" range, the
port1
relay does not switch, applying voltage to the other E-lock. In the settings of the
I/O module (program P18), set the following for port 1: the corresponding trip time
of this port in seconds (for instance OU1
4
) and function No. 1 (Nrf1-1).
After entering the program "
From
" will be displayed - the unit waits for the value
to be entered (1 - 255) which corresponds to the uniphone physical addresses. 1-
digit and 2-digit values must be confirmed by pressing the "
key
" button, while a
3-digit value is saved by the unit automatically without confirmation. Then "
TO
"
will be displayed - the unit waits for the value to be entered (1 - 255) which
corresponds to the uniphone physical addresses.
Connection:
Connect the E-lock output from the unit (terminal "- ELOCK") to the "N" terminal
of the I/O module, and the E-lock to the "NC" and "NO" outputs of the module,
respectively. The "+ ELOCK" terminal is connected together to E-locks.
P25 LINE TEST - TESTING UNIPHONES IN THE INSTALLATION
LTest
This program is used to test whether or not the uniphones in the installation cause
interference when dialling addresses. The program will find potential uniphones
in the installation with faulty address switching or decoding system.