Chapter
4 Configuration
Installation and Operation Manual
4-92
Configuring for Operation
ACE-3105, ACE-3205 Ver. 5.2
Parameter Description
Possible
Values
Tunnel source IP
The source IP address of the IP header on
which the GRE is running.
Note:
•
The IP address must either be a system
address or one of the configured router
interfaces, otherwise an error message
is returned.
•
This parameter only appears if the
interface type is set to GRE.
Valid IP address
Default: 0.0.0.0
Tunnel
destination IP
The destination IP address of the layer on
which the GRE is running.
Note:
•
The IP address must be associated with
a known route, otherwise an error
message is returned.
•
This parameter only appears if the
interface type is set to GRE.
Valid IP address
Default: 0.0.0.0
Management
access
Enables or disables management access
(SNMP, Telnet, SSH, Web, SSL) via this
router interface.
Enable
Disable
Default: Enable
•
If a router interface has been created for the VCL interface (ADSL2+ interface
or IMA Group over SHDSL), there are two options:
o
The VCL interface was already configured via the VCL Interface menu
with atmConfVcConnected set to VAL_atmConfVcConnected_bridgePort.
In this case, it must be set to Bridged PDU.
o
The VCL interface is created during this session the same together with
all the other ATM Router Interfaces. In this case, it must be set to
Routed PDU.
•
The only router interface parameters that can be changed on the fly, is
'Management access'.
•
The number of ATM-type router interfaces is limited to 2.
•
The maximum number of PW type router interfaces is 2.
•
The maximum number of bridge type interfaces is 1.
Setting the Static Route Parameters
For remote manager IPs and peers that are located in a subnet different than
that of the router interface, you need to assign static route parameters.
³
To access the static route parameters:
•
From the Router menu (see
), select Static Route.
The Static Route menu is displayed.
Note
Содержание ACE-3105
Страница 1: ...ACE 3105 ACE 3205 Cell Site Gateways Version 5 2 INSTALLATION AND OPERATION MANUAL The Access Company...
Страница 2: ......
Страница 352: ...Chapter 6 Monitoring and Diagnostics Installation and Operation Manual 6 114 Technical Support ACE 3105 ACE 3205 Ver 5 2...
Страница 380: ...Appendix D Clock Modes Installation and Operation Manual D 8 DSL and PSN Timing Modes ACE 3105 ACE 3205 Ver 5 2...
Страница 396: ...Appendix E Encapsulation over PSN Installation and Operation Manual E 16 5BClock Encapsulation ACE 3105 ACE 3205 Ver 5 2...
Страница 414: ......
Страница 416: ......
Страница 417: ......