Chapter
6 Monitoring and Diagnostics
Installation and Operation Manual
6-100
Recovering ACE Units
ACE-3105, ACE-3205 Ver. 5.2
³
To install the new fan tray:
1.
Carefully check the fan tray for foreign objects and dirt that may have been
trapped inside, and remove them.
2.
Insert the fan tray in the left chassis slot, and slide it in until its rear
connector engages the mating connector on the backplane.
3.
Secure the fan tray by tightening its two screws using a flathead screwdriver.
Changing the Power Supply Module
³
Before deciding on changing the PS module:
•
Verify there was no momentary power failure causing a PS flip
•
Check that the power source is operative.
³
To remove a hot-swappable power supply unit:
1.
Make sure to disconnect the power supply cable before removing the power
supply module.
2.
Using a flathead screwdriver, unscrew the two tightening screw that secure
the unit to the chassis.
3.
Carefully pull and remove the power supply unit from the chassis.
³
To install the hot-swappable power supply unit:
1.
Carefully slide the new power supply unit into its slot until the unit's rear
connector engages the mating connector on the backplane, and the power
supply unit fits into its place.
2.
Using a flathead screwdriver, secure the PS unit with the two tightening
screws.
Connecting to AC Power
AC power is supplied to ACE-3400, ACE-3402 via a 3-prong plug. AC power should
be supplied through the 1.5m (5 ft) standard power cable terminated by a 3-
prong plug. The cable is provided with the unit.
Two power cables may be connected to the unit simultaneously.
Redundant Main Modules (MC)
ACE-3600, ACE-3400 and ACE-3402 allow installing two main modules to ensure
continuous operation when one module is reset, restarted, or stops operating for
any reason. In such cases, the redundant main module immediately takes over
the unit, using its own pre-configured settings.
This protective mechanism is available provided that the following conditions are
met:
Содержание ACE-3105
Страница 1: ...ACE 3105 ACE 3205 Cell Site Gateways Version 5 2 INSTALLATION AND OPERATION MANUAL The Access Company...
Страница 2: ......
Страница 352: ...Chapter 6 Monitoring and Diagnostics Installation and Operation Manual 6 114 Technical Support ACE 3105 ACE 3205 Ver 5 2...
Страница 380: ...Appendix D Clock Modes Installation and Operation Manual D 8 DSL and PSN Timing Modes ACE 3105 ACE 3205 Ver 5 2...
Страница 396: ...Appendix E Encapsulation over PSN Installation and Operation Manual E 16 5BClock Encapsulation ACE 3105 ACE 3205 Ver 5 2...
Страница 414: ......
Страница 416: ......
Страница 417: ......