Chapter
6 Monitoring and Diagnostics
Installation and Operation Manual
6-20
Monitoring Performance
ACE-3105, ACE-3205 Ver. 5.2
ACE-3205 – RAD Data Communications
Monitoring> Physical layer > Port > ADSL2+ > Statistics
FEC ... (0)
LOSS ... (0)
LOFS ... (0)
CRC anomalies ... (0)
ES ... (0)
SES ... (0)
UAS ... (0)
Time elapsed ... (0)
Valid intervals ... (0)
1. Interval ... (0)
2. Port number ... (1)
>
Please select item <1 to 2>
ESC-Previous menu; !-Main menu; &-Exit; @-Debug
Figure
6-18. ADSL2+ Port Statistics
Table
6-15. ADSL2+ Port Statistics
Parameter Description
Possible
Values
FEC
Number of Forward Error Correction
events. This parameter is inhibited
during UAS or SES.
LOSS
Number of seconds with Loss Of
Signal defect.
LOFS
Number of seconds with Loss of
Framing failures.
CRC anomalies
Number of errors detected by cyclic
redundancy checks.
ES
Number of ‘Errored Seconds’. This
parameter is a count of 1-second
intervals with one or more CRC-8
anomalies summed up over all
received bearer channels, or one or
more LOS defects, or one or more
SEF defects, or one or more LPR
defects. This parameter is inhibited
during UAS.
Содержание ACE-3105
Страница 1: ...ACE 3105 ACE 3205 Cell Site Gateways Version 5 2 INSTALLATION AND OPERATION MANUAL The Access Company...
Страница 2: ......
Страница 352: ...Chapter 6 Monitoring and Diagnostics Installation and Operation Manual 6 114 Technical Support ACE 3105 ACE 3205 Ver 5 2...
Страница 380: ...Appendix D Clock Modes Installation and Operation Manual D 8 DSL and PSN Timing Modes ACE 3105 ACE 3205 Ver 5 2...
Страница 396: ...Appendix E Encapsulation over PSN Installation and Operation Manual E 16 5BClock Encapsulation ACE 3105 ACE 3205 Ver 5 2...
Страница 414: ......
Страница 416: ......
Страница 417: ......