Note
Action
xx1800002489
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate.
5
xx1800002490
Disconnect the connector.
•
J2.FB2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
6
xx1800002491
Snap loose and remove the female head of the
connector from the connector plate.
7
xx1800002492
Remove the swing cover.
8
Continues on next page
Product manual - IRB 1100
183
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.2 Replacing the lower cable package
Continued