Note
Action
Screw: M3x5 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Remove the screws.
Replace with a new cooling pad and then refit the
screws.
4
Tightening torque: 1.2 Nm
xx1800003026
Motor orientation: orient the motor
according to the figure below, in
regard to the encircled motor con-
nector.
xx1800003027
Orient the motor correctly and fit it into the swing.
Tip
Bend the motor signal cable back towards the
swing support.
5
Screw: M4x16 12.9 Lafre
2C2B/FC6.9 (3 pcs)
Refit the screws and washers.
Note
Do not tighten the screws yet.
6
Washer, 3HAC063985-001 (3 pcs)
xx1800002494
Continues on next page
Product manual - IRB 1100
623
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.8.1 Replacing the axis-1 gearbox
Continued