Note
Action
WARNING
The robot is likely to be mechanically unstable if
not secured to the foundation.
4
xx1800003033
Loosen the robot from the foundation by removing
the foundation attachment screws and put the
robot on its side.
5
Disconnecting the SMB connectors
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page 49
2
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
3
Continues on next page
586
Product manual - IRB 1100
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.8.1 Replacing the axis-1 gearbox
Continued