Refitting the lower cable package
Use these procedures to refit the lower cable package.
Refitting the brake release button
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
brake release button assembly
tool, included in the special toolkit
3HAC071022-001
xx1800003040
Refit the brake release button.
Note
Do not reconnect the connector yet.
Do not tighten the button yet.
2
Refitting the lower cable package through the axis-1 gearbox
Notice that the procedure differs depending on if the connector interface is located
either at the rear or at the bottom of the base.
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
xx1800003046
Refit the pulley cover to the lower cable package.
2
Continues on next page
Product manual - IRB 1100
199
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.2 Replacing the lower cable package
Continued
Содержание IRB 1100
Страница 1: ...ROBOTICS Product manual IRB 1100 ...
Страница 2: ...Trace back information Workspace 22C version a10 Checked in 2022 09 29 Skribenta version 5 5 019 ...
Страница 8: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 38: ...This page is intentionally left blank ...
Страница 50: ...This page is intentionally left blank ...
Страница 738: ...This page is intentionally left blank ...
Страница 760: ...This page is intentionally left blank ...
Страница 764: ......
Страница 765: ......