Note
Action
xx1800003299
Valid for IRB 1100-4/0.475
Separate the wrist from the housing.
4
xx1800003298
Valid for IRB 1100-4/0.58
Separate the extender unit and wrist from the
housing.
5
Removing the axis-4 gearbox
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
CAUTION
Removing gearboxes will release axes. This
means the axes can fall down.
Make sure axes are well supported before remov-
ing gearboxes.
3
Continues on next page
460
Product manual - IRB 1100
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.6.2 Replacing the extender unit and wrist
Continued