Note
Action
Tightening torque: 0.3 Nm
xx1800002468
Reconnect the connectors.
•
SMB.P7
•
SMB.J1
•
SMB.J2
Tip
See the number markings on the connectors for
help to find the corresponding connector.
3
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
4
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (6 pcs)
Refit the SMB cover to the base.
5
Tightening torque: 1.2 Nm
xx1800002467
Concluding procedure
Note
Action
For robots with protection type Clean Room:
1
Clean and paint the joints that have been opened.
See
Cut the paint or surface on the robot before
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
Calibration is detailed in section
Recalibrate the robot.
2
Continues on next page
Product manual - IRB 1100
117
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
4 Maintenance
4.6.1 Replacing the battery pack
Continued
Содержание IRB 1100
Страница 1: ...ROBOTICS Product manual IRB 1100 ...
Страница 2: ...Trace back information Workspace 22C version a10 Checked in 2022 09 29 Skribenta version 5 5 019 ...
Страница 8: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 38: ...This page is intentionally left blank ...
Страница 50: ...This page is intentionally left blank ...
Страница 738: ...This page is intentionally left blank ...
Страница 760: ...This page is intentionally left blank ...
Страница 764: ......
Страница 765: ......