Note
Action
xx2000000305
Secure the small circular plate with screws.
6
xx1900002156
Place the large circular plate of the radial sealing
fitting tool against the radial sealing and fix with
six M6x50 screws.
7
Screw the screws, little by little and evenly, to
press the sealing into place.
8
Remove the assembly tool.
9
Check that the sealing is undamaged and properly
fitted.
10
Placing the axis-1 mechanical stop
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Mechanical stop, axis 1:
3HAC061947-001
Check the axis-1 mechanical stop.
Replace if damaged.
2
Continues on next page
Product manual - IRB 1100
257
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued
Содержание IRB 1100
Страница 1: ...ROBOTICS Product manual IRB 1100 ...
Страница 2: ...Trace back information Workspace 22C version a10 Checked in 2022 09 29 Skribenta version 5 5 019 ...
Страница 8: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 38: ...This page is intentionally left blank ...
Страница 50: ...This page is intentionally left blank ...
Страница 738: ...This page is intentionally left blank ...
Страница 760: ...This page is intentionally left blank ...
Страница 764: ......
Страница 765: ......