Parameterization
D184B140U02 FSM4000
95
Pos: 35.9 /Überschriften/1.1.1/1-spaltig/Neuabgleich der Spulentemperatur @ 16\mod_1196859777171_3101.doc @ 144585
7.4.3 Readjusting the coil temperature
Pos: 35.10 /Konfiguration, Parametrierung/Durchfluss/FSM4000/Erweiterte Diagnosefunktionen/Neuabgleich Spulentemperatur @ 16\mod_1196859641593_3101.doc @ 144562
If a readjustment is required, make sure that the flowmeter sensor and coil are relatively close
to ambient temperature. You might need to allow the flowmeter to cool off overnight.
Work steps:
• Switch on the transmitter.
• Under "Diagnostics / Adjustment / CabLength", enter or check the cable length.
• Enter the ambient temperature in the submenu "Diagnostics / Adjustment / Coil Temp".
• Store the new reference resistance in the submenu "Diagnostics / Adjustment / Transfer
RT20".
Pos: 36 /Konfiguration, Parametrierung/Durchfluss/FSM4000/Software-Historie/Software-Historie @ 16\mod_1196860571562_3101.doc @ 144633
7.5 Software
history
7.5.1 For
transmitters
without
communication or HART protocol
Software D200S021U01
Software Version Type of changes
Documentation/supplements
B.10 OEM
software
−
B.11
Improve min. contrast limit.
After changing from 50
→
60 Hz the
system data now displays the correct
frequency.
−
B.12
Shortened Finnish texts.
Aut. simulator detection for counter
management improved.
−
B.14
Improved FRAM management.
−
B.20
Added Turkish as new language.
Added error E (DC too high)
Updated flowmeter sensor 10D1462/72.
Added documentation for the
additional points.
B.22
Always display the flowrate with 4 decimal
places.
−
B.30
Menu item for noise reduction
Menu item Meter factor
Support for flowmeter sensor
SE21, DN 1 ... DN 2
Added documentation for the
additional points.
B.31 Hardware
compatibility for C-level
hardware
−
B.32
Improved totalizer management
−
B.33/B.34
Improved FRAM management
−
C.10
Extended diagnostic functions.
Extended noise reduction by 2 more levels.
Software supports external zero point
adjustment via contact input.
Added documentation for the
additional points.