![ABB FSM4000 Series Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/abb/fsm4000-series/fsm4000-series_operating-instruction_3770914065.webp)
Parameterization
D184B140U02 FSM4000
65
Submenu/parameter
Value range
Comment
Submenu
Data 60 Hz
This menu does not appear with an excitation frequency
of 50 Hz or 70 Hz.
Channel
-123
µs
View only
Adjustment value for Channel can be monitored for the
excitation frequency setting (displayed when an older
sensor 60 Hz has been selected).
Zero
View
only
0
%
Adjustment value for Zero can be monitored for the
excitation frequency setting (displayed when an older
sensor 60 Hz has been selected).
Span
→
V
View
only
91
%
Adjustment value for Span Forward can be monitored for
the excitation frequency setting (displayed when an older
sensor 60 Hz has been selected).
Span
←
R
View
only
-91
%
Adjustment value for Span Reverse can be monitored for
the excitation frequency setting (displayed when an older
sensor 60 Hz has been selected).
Submenu
Data 70 Hz
This menu does not appear with an excitation frequency
of 50 Hz or 60 Hz.
Channel
-123
µs
View only
Adjustment value for Channel can be monitored for the
excitation frequency setting (displayed when a new
sensor has been selected).
Zero
View
only
0 %
Adjustment value for Zero can be monitored for the
excitation frequency setting (displayed when a new
sensor has been selected).
Span
→
V
View
only
91
%
Adjustment value for Span Forward can be monitored for
the excitation frequency setting (displayed when a new
sensor has been selected).
Span
←
R
View
only
-91
%
Adjustment value for Span Reverse can be monitored for
the excitation frequency setting (displayed when a new
sensor has been selected).
Submenu
Data Iout
This menu does not appear for the PROFIBUS or
FOUNDATION fieldbus.
Adjust
Iout
4
mA
View
only
4.0
mA
Display adjustment value for transmitter for the current
output at 4.0 mA.
Adjust
Iout
4
mA
View
only
20.0
mA
Display adjustment value for transmitter for the current
output at 20.0 mA.