Installation
D184B140U02 FSM4000
23
Pos: 18.8 /Montage/Durchfluss/FSM4000/Drehmomentangaben (BA) @ 14\mod_1193664742937_3101.doc @ 134731
4.4 Torque
information
4.4.1 Flanged flowmeter model SE41F / SE21F
Meter size DN
Nominal
pressure
Max. tightening torque
mm
Inch
PN
Screws
Nm
40
4 x M12
8
CL 150
4 x M12
6
3 ... 10
1)
1/10 ... 3/8“
1)
CL 300
4 x M12
7
40
4 x M12
10
CL 150
4 x M12
6
15 1/2“
CL 300
4 x M12
7
40
4 x M12
16
CL 150
4 x M12
8
20 3/4“
CL 300
4 x M16
13
40
4 x M12
21
CL 150
4 x M12
10
25 1“
CL 300
4 x M16
18
40
4 x M16
34
CL 150
4 x M12
15
32 1
1/4“
CL 300
4 x M16
27
40
4 x M16
43
CL 150
4 x M12
20
40 1
1/2“
CL 300
4 x M20
43
40
4 x M16
56
CL 150
4 x M16
39
50 2“
CL 300
8 x M16
28
16
4 x M16
34
40
8 x M16
39
CL 150
4 x M16
49
65 2
1/2“
CL 300
8 x M20
43
40
8 x M16
49
CL 150
4 x M16
69
80 3“
CL 300
8 x M20
62
16
8 x M16
47
40
8 x M20
77
CL 150
8 x M16
49
100 4“
CL 300
8 x M20
92
16
8 x M16
62
40
8 x M24
120
CL 150
8 x M20
76
125 5“
CL 300
8 x M20
120
16
8 x M20
83
40
8 x M24
155
CL 150
8 x M20
96
150 6“
CL 300
8 x M20
100
10
8 x M20
120
16
12 x M20
81
25
12 x M24
120
40
12 x M27
200
CL 150
8 x M20
135
200 8“
CL 300
12 x M24
170
Continued on next page