DCS500 Pin and Parameter list
A 109
Group 124: TORQUE REFERENCE CHAIN
SEL1:OUT
Signal of TORQ_REF_SELECTION-function block
( S6/16 )
Torque reference from torque reference chain .
12401
FB_O: I2
SC: TORQ
HL: -
LL: -
D: -
U: %
SEL2:OUT
Signal of TORQ_REF_HANDLING-function block
( S7/16 )
Torque reference after torque reference selector .
12402
FB_O: I2
SC: TORQ
HL: -
LL: -
D: -
U: %
SEL2:TORQ/SPEED
Signal of TORQ_REF_HANDLING-function block
( S7/16 )
An output indicating which control mode is active:
0 = speed control is active
-1 = torque control is active.
12403
FB_O: B
SC: BO
HL: -
LL: -
D: -
U: -
SEL2:IN_LIM
Signal of TORQ_REF_HANDLING-function block
( S7/16 )
An output indicating that torque reference is in limit:
0 = reference between limits
-1 = reference has reached limit / is limited
12404
FB_O: B
SC: BO
HL: -
LL: -
D: -
U: -