Functional Software description
40
DCS 500 Software Description
GEAR.TORQ TIME (2316)
is the time period after the direction
change when
GEAR.START TORQ
torque limit is used. Scale: 1 =
1 ms.
GEAR.TORQ RAMP (2317)
defines the rate of change for the
torque limit when
GEAR.TORQ TIME
has elapsed.
GEAR.TORQ
RAMP
is given as the maximum change of torque limit in 3.3 ms
(50Hz). Scale: 4000 = nominal torque of motor
3.3 ms (50 Hz)
2.8 ms (60 Hz)
GEAR.TORQ RAMP
GEAR.TORQ
TIME
t
T
Torque
reference sum
Reference jump
without backlash
compensation
GEAR.START
TORQUE
Figure 21
Gear backlash compensation principle