DCS500 Pin and Parameter list
A 14
Group 3: BRAKE CONTROL
[HOLD_REF]
Input of BRAKE CONTROL-function block.
( S10/16 )
Holding torque used when the drive is running during START_DELAY or STOP_DELAY.
301
FB_I: C4
SC: TORQ
HL: 19999
LL: 0
D: 0
U: -
[BR_RELEASE]
Input of BRAKE CONTROL-function block.
( S10/16 )
The release command for the mechanical brake.
302
FB_I: C4
SC: BI
HL: 19999
LL: 0
D: 10715
U: -
[MIN_SP_IND]
Input of BRAKE CONTROL-function block.
( S10/16 )
Indicating that speed actual is below a minimum speed limit.
303
FB_I: C4
SC: BI
HL: 19999
LL: 0
D: 12201
U: -
[ACT_BRAKE]
Input of BRAKE CONTROL-function block.
( S10/16 )
Acknowledge signal from the brake. This input points to the signal, it is connected to. The
logic level on this interconnection is defined as:
0 =
(brake is closed)
<> =
(brake is open).
If the acknowledge is not used, set [ACT_BRAKE] = 0, otherwise connect it to Digital Input
or some other function block. When brake is opened with LIFT_BRAKE (10304) output,
[ACT_BRAKE] has to indicate OPEN-status within 5 seconds, if not, the drive will trip.
304
FB_I: C4
SC: BI
HL: 19999
LL: 0
D: 0
U: -
START_DELAY
Parameter of BRAKE CONTROL-function block.
( S10/16 )
When start command is given, speed reference is released after START_DELAY has
elapsed.
305
FB_P: I2
SC: 1
HL: 32767
LL: 0
D: 0
U: ms
STOP_DELAY
Parameter of BRAKE CONTROL-function block.
( S10/16 )
When stop command is given, current control is blocked when STOP_DELAY has
elapsed.
306
FB_P: I2
SC: 1
HL: 32767
LL: 0
D: 0
U: ms
HOLD_TORQ
Parameter of BRAKE CONTROL-function block.
( S10/16 )
Torque reference used when the drive is running during START_DELAY or STOP_DELAY
if [HOLD_REF]
is not connected
.
307
FB_P: I2
SC: TORQ
HL: 16000
LL: -16000
D: 0
U: %
EMESTOP_BRAKE
Parameter of BRAKE CONTROL-function block.
( S10/16 )
Selects the function of mechanical brake in emergency stop situation:
0 = DISABLE
(brake is activated when speed is zero)
1 = ENABLE
(brake is activated immediately).
308
FB_P: E2
SC: -
HL: 1
LL: 0
D: 0
U: -