A 89
Group 111: FAULTS, ALARMS
FAULT_WORD_1
Signal of FAULT HANDLING function block
( S16/16 )
Fault status word where each bit represents one fault status.
If fault is active, corresponding bit is set.
B0
Auxil. undervoltage
B1
Overcurrent
B2
Armature overvoltage
B3
Converter overtemp.
B4
Earth fault
B5
Motor 1 overtemp.
B6
Motor 1 overload
B7
I/O-Board not found
B8
Motor 2 overtemp
B9
Motor 2 overload
B10
No BRAKE ack
B11
Mains undervoltage
B12
Mains overvoltage
B13
Not in synchronism
B14
Field ex.1 overcurr
B15
Field ex.1 comerror
11101
S: PB
SC: -
HL: -
LL: -
D: -
U: -
FAULT_WORD_2
Signal of FAULT HANDLING function block
( S16/16 )
Fault status word where each bit represents one fault status.
If fault is active, corresponding bit is set.
B0
Arm. current ripple
B1
Field ex.2 overcurr
B2
Field ex.2 comerror
B3
Phase sequence fault
B4
No field ack.
B5
Speed meas. fault
B6
No ext. FAN ack.
B7
No main cont. ack.
B8
Type coding fault
B9
Backup read fault
B10
No C FAN ack
B11
Local & disconnected
B12
Field ex.1 not OK
B13
Field ex.2 not OK
B14
Motor stalled
B15
Motor overspeed.
11102
S: PB
SC: -
HL: -
LL: -
D: -
U: -