DCS500 Pin and Parameter list
A 27
Group 9: DRIVE LOGIC
[ON/OFF]
Input of DRIVE LOGIC-function block.
( S3/16 )
Control of the main contactor.
901
FB_I: C4
SC: BI
HL: 19999
LL: 0
D: 10713
U: -
[RUN1]
Input of DRIVE LOGIC-function block.
( S3/16 )
One of three RUN-commands. All run commands release controllers of the drive.
902
FB_I: C4
SC: BI
HL: 19999
LL: 0
D: 10715
U: -
[RUN2]
Input of DRIVE LOGIC-function block.
( S3/16 )
One of three RUN-commands. All run commands release controllers of the drive.
903
FB_I: C4
SC: BI
HL: 19999
LL: 0
D: 11902
U: -
[RUN3]
Input of DRIVE LOGIC-function block.
( S3/16 )
One of three RUN-commands. All run commands release controllers of the drive.
904
FB_I: C4
SC: BI
HL: 19999
LL: 0
D: 0
U: -
[COAST_STOP]
Input of DRIVE LOGIC-function block.
( S3/16 )
Coast stop-command. This command will stop the drive so that the motor is left running
and friction together with the load will decelerate the speed to zero.
905
FB_I: C4
SC: BI
HL: 19999
LL: 0
D: 0
U: -
[EME_STOP]
Input of DRIVE LOGIC-function block.
( S3/16 )
Emergency stop-command. This command will stop the drive in a way which is defined
with the parameter EME_STOP_MODE (917).
906
FB_I: C4
SC: BI
HL: 19999
LL: 0
D: 10709
U: -
[RESET]
Input of DRIVE LOGIC-function block.
( S3/16 )
Reset-command. This command will reset all fault memories if corresponding fault
indication is not active any more.
907
FB_I: C4
SC: BI
HL: 19999
LL: 0
D: 10711
U: -
[START_INHIBIT]
Input of DRIVE LOGIC-function block.
( S3/16 )
Start inhibit-command. This command will disable ON- and RUN-commands to the drive.
If the drive is running when this command is activated, the current controler tries to
decrease the current to zero as fast as possible. If a 12 pulse parallel configuration is in
use, please check signal LOGIK_F.INHIBIT (13616).
908
FB_I: C4
SC: BI
HL: 19999
LL: 0
D: 0
U: -
[DISABLE_LOCAL]
Input of DRIVE LOGIC-function block.
( S3/16 )
Disable local-command. This command will disable local control of the drive from either a
panel or CMT.
909
FB_I: C4
SC: BI
HL: 19999
LL: 0
D: 0
U: -
[ACK_CONV_FAN]
Input of DRIVE LOGIC-function block.
( S3/16 )
An acknowledge signal from converter fan contactor. The drive will not start if there is no
acknowledge from the converter fan contactor after the FAN_ON (10908)-command.
910
FB_I: C4
SC: BI
HL: 19999
LL: 0
D: 10701