DCS500 Pin and Parameter list
A 71
FIELDBUS_PAR.7
Parameter of FIELDBUS-function block.
(S12/16 ).
Fieldbus parameter with adapter specific function
PROFIBUS (NPBA-02)
CUT-OFF TIMEOUT
0 to 255
PROFIBUS (NPBA-12)
CUT-OFF TIMEOUT
0 to 255
AC31
DATA SET1 CONST
0 … 32767 (1 = 6ms)
MODBUS
BAD MESSAGES
read only
GD Out 2
0 ... 96
CANopen
STATUS
read only
(0) SELF TEST
(1) RX Q OVERRUN
(2) CAN OVERRUN
(3) BUS OFF
(4) ERROR SET
(5) ERROR RESET
(6) TX Q OVERRUN
(7) DISCONNECTED
(8) STARTED
(9) STOPPED
(10) G FAILS
(11) PRE-OPERAT
(12) RESET COMM.
(13) RESET NODE
DeviceNet
POLL/COS INPUT SEL
(0) BASIC SPEED
(1) TRANSPARENT
(2) PARAMETERS
(3) MUL. DATASETS
4007
FB_P: I2
SC: 1
HL: 32767
LL: 0
D: 0
U: -
FIELDBUS_PAR.8
Parameter of FIELDBUS-function block.
(S12/16 ).
Fieldbus parameter with adapter specific function
PROFIBUS (NPBA-02)
COMM PROFILE
(0) ABB DRIVES
(1) CSA 2.8/3.0
PROFIBUS (NPBA-12)
COMM PROFILE
(0) ABB DRIVES
(1) CSA 2.8/3.0
AC31
DATA SET2 CONST
0 … 32767 (1 = 6ms)
MODBUS
DDCS CHANNEL
(0) CH0'
(1) CH3
GD Out 3
0 ... 96
CANopen
DATA SET INDEX
(0) FBA D SET 1
(1) FBA D SET 10
DeviceNet
COS DATA OUTPUT
(0) BASIC SPEED
(1) TRANSPARENT
(2) PARAMETERS
(3) MUL. DATASETS
4008
FB_P: I2
SC: 1
HL: 32767
LL: 0
D: 0
U: -
Содержание DCS 500B
Страница 8: ......
Страница 102: ...Functional Software description 94 DCS 500 Software Description ...
Страница 105: ...DCS 500 Thyristor Power converters Parameter and Signal list Software Version 21 233 Diagram S21V2_0 Appendix A ...
Страница 227: ......