DCS500 Pin and Parameter list
A 37
WRITE_ENABLE_KEY
Parameter of MAINTENANCE-function block.
( S2/16 )
Save the parameter access
This is the key number
1207
FB_P: I2
SC: 1
HL: 1000
LL: 1
D: 358
U: -
WRITE_ENABLE_PIN
Parameter of MAINTENANCE-function block.
( S2/16 )
Save the parameter access
This is the personality identify number. Parameter access is only possible if
WRITE_ENABLE_KEY and WRITE_ENABLE_PIN numbers are equal.
1208
FB_P: I2
SC: 1
HL: 1000
LL: 1
D: 358
U: -
SELECT_OPER.SYST.
Parameter of MAINTENANCE-function block.
( S2/16 )
Select the operation mode of converter:
0 = 6P-SINGLE
(6-pulse single mode, default)
1 = 12P-MASTER
(12-pulse master mode)
2 = 12P-SLAVE
(12-pulse slave mode)
1209
FB_P: E2
SC: -
HL: 2
LL: 0
D: 0
U:-
ACTUAL VALUE 1
Input of MAINTENANCE-function block.
( S2/16 )
Pointer to actual value 1 on panel.
1210
FB_I: C4
SC: -
HL: 19999
LL: 0
D: 12103
U: -
ACTUAL VALUE 2
Input of MAINTENANCE-function block.
( S2/16 )
Pointer to actual value 2 on panel.
1211
FB_I: C4
SC: -
HL: 19999
LL: 0
D: 10501
U: -
ACTUAL VALUE 3
Input of MAINTENANCE-function block.
( S2/16 )
Pointer to actual value 3 on panel.
1212
FB_I: C4
SC: -
HL: 19999
LL: 0
D: 10505
U: -
FIELDBUS NODE ADDR
Parameter of MAINTENANCE-function block.
( S2/16 )
In case a field bus module Nxxx-0x is used keep this parameter to default. If a serial link
has to be established please handle this parameter according to the AC70 documentation.
1213
FB_P: I2
SC: 1
HL: 255
LL:1
D: 1
U: -
MACRO_SELECT
Parameter of MAINTENANCE-function block.
( S2/16 )
Select the macros:
0 = NONE
(no macro selected)
1 = MACRO 1
(macro 1 selected)
2 = MACRO 2
(macro 2 selected)
3 = MACRO 3
(macro 3 selected)
4 = MACRO 4
(fieldbus macro selected)
1214
FB_P: E2
SC: -
HL: 4
LL: 0
D: 0
U: -