VLAN Type
This field is applicable when you select
Add
or
Exchange
in the
Action
field.
Select a standard Ethernet type code identifying the frame and indicates whether
the frame carries IEEE 802.1Q or IEEE802.1ad tag information.
For untagged frames, the system sets the VLAN type to 8100 regardless of your
setting here.
For tagged frames, the system sets the VLAN type (
8100
,
88A8
or
9100
) that you
specify.
VLAN ID
Enter a VLAN ID (from 1 to 4094) of the packet.
If you select
Exchange
in the
Action
field, this replaces the packet’s VLAN ID.
Priority Src
Select
Original
if you don’t want to change the priority of the packets.
Select
Priority Profile
to change the packet priority based on the settings in the
priority profile configured for the ONU in the
ONU Setup
screen. If no priority
settings are configured for the matched packets, the TOS-COS settings in the
Priority Profile
screen apply.
Downstream
Default VLAN
Rule
Configure the default settings for the incoming traffic (from the OLT to the ONU) that
does not match any VLAN rule.
Action
Specify the action to perform on the packets.
Select
Delete
to delete a VLAN tag from the incoming packets.
Select
Exchange
to replace the VID with the one specified in the
VLAN ID
field.
Select
None
to send the packets without any changes.
VLAN ID
Enter the VLAN ID (from 1 to 4094).
If you select
Delete
, the ONU deletes the outer VLAN tag (that matches this VLAN
ID) from incoming packets.
If you select
Exchange
in the
Action
field, this replaces the packet’s VLAN ID.
Priority Src
Select
Original
if you don’t want to change the priority of the packets.
Select
Priority Profile
to change the packet priority based on the settings in the
priority profile configured for the ONU in the
ONU Setup
screen. If no priority
settings are configured for the matched packets, the TOS-COS settings in the
Priority Profile
screen apply.
Index
This field displays the index number for the VLAN rule.
Active
Select this option to enable the VLAN rule.
Direction
This field displays the direction of the traffic to which the rule applies.
Upstream means traffic from the ONU to the OLT while downstream traffic goes
from the OLT to the ONU.
Classifier
Specify the packet type to check. Choices are
Ethertype
,
IPv4 Protocol
and
VLAN
.
Select
Ethertype
to check the Ethernet type of the packet.
Select
IPv4 Protocol
to check the IPv4 protocol number of the packet.
Select
VLAN
to check the VLAN ID of the packet.
Value
Enter the packet type value to check.
If you select
Ethertype
in the
Classifier
field, enter the Ethernet type number in
hexadecimal value (0x0000 - 0xff0f). The 0x prefix is already entered for you. Refer
for common Ethernet type numbers.
If you select
IPv4 Protocol
in the
Classifier
field, enter an IPv4 protocol number (1-
255). Refer to
for common protocol numbers.
If you select
VLAN
in the
Classifier
field, enter a VID (1-4094).
Table 23
EPON VLAN Profile Setup (continued)
LABEL
DESCRIPTION
Summary of Contents for OMC-2301
Page 1: ...www zyxel com OMC 2301 GEPON OLT Management Card User s Guide Version 3 60 11 2007 Edition 1...
Page 2: ......
Page 7: ...Safety Warnings OMC 2301 User s Guide 7...
Page 8: ...Safety Warnings OMC 2301 User s Guide 8...
Page 10: ...Contents Overview OMC 2301 User s Guide 10...
Page 18: ...Table of Contents OMC 2301 User s Guide 18...
Page 22: ...List of Figures OMC 2301 User s Guide 22...
Page 25: ...25 PART I Introduction Introducing the OMC 27 Hardware 31...
Page 26: ...26...
Page 30: ...Chapter 1 Introducing the OMC OMC 2301 User s Guide 30...
Page 34: ...Chapter 2 Hardware OMC 2301 User s Guide 34...
Page 36: ...36...
Page 46: ...Chapter 4 Initial Setup Example OMC 2301 User s Guide 46...
Page 51: ...Chapter 5 System Status and Port Statistics OMC 2301 User s Guide 51...
Page 78: ...78...
Page 82: ...Chapter 7 Classifier Filter Profile OMC 2301 User s Guide 82...
Page 92: ...Chapter 8 VLAN Profile OMC 2301 User s Guide 92...
Page 100: ...Chapter 10 Static MAC Forward Setup OMC 2301 User s Guide 100...
Page 104: ...Chapter 11 Destination Filter OMC 2301 User s Guide 104...
Page 121: ...121 PART IV Management Maintenance 123 Diagnostic 131 Syslog 133 MAC Table 137 IGMP Table 141...
Page 122: ...122...
Page 136: ...Chapter 16 Syslog OMC 2301 User s Guide 136...
Page 140: ...Chapter 17 MAC Table OMC 2301 User s Guide 140...
Page 142: ...Chapter 18 IGMP Table OMC 2301 User s Guide 142...
Page 144: ...144...
Page 174: ...Chapter 19 Introducing the Commands OMC 2301 User s Guide 174...
Page 190: ...Chapter 20 Command Examples OMC 2301 User s Guide 190...
Page 208: ...208...
Page 212: ...Appendix A Legal Information OMC 2301 User s Guide 212...
Page 218: ...Appendix B Customer Support OMC 2301 User s Guide 218...
Page 224: ...Index OMC 2301 User s Guide 224...