1-25
IM AQ1210-01EN
Features
1
2
3
4
5
6
7
8
9
10
11
App
Index
Executing the Multi-Core Loss Test
First, start the multi-core loss test on the master instrument. The core number information of the
cores to be tested is transmitted from the master side through the optical fiber cable for signal
transmission. When the core numbers to be measured are received through the OPM port, the
slave instrument will be ready to execute a multi-core loss test.
Execute the multi-core loss test on the slave side. The light to be measured is output from the
OTDR port (PORT1) on the slave side. This light enters the OPM port on the master side, and
the loss in the optical fiber cable with the target core number is measured.
The measurement results are sent from the master to the slave instrument through the optical
fiber cable for signal transmission.
AQ1210A, AQ1215A,
AQ1210E, AQ1215E,
AQ1215F, AQ1216F
AQ1210A, AQ1215A,
AQ1210E, AQ1215E,
AQ1215F, AQ1216F
Master (this instrument)
Execute a multicore loss test
Slave (this instrument)
Optical fiber cable for signal transmission
OTDR port (PORT1)
OPM port
Transfer the results of the multicore loss test
Optical fiber cable under
multicore loss test
OTDR port
(PORT1)
OPM port
Light being measured
If you cancel an ongoing multi-core loss test, the completed portion of the measurement results
are held, so you can resume the test from the optical fiber cable with the next target core
number.
Advanced Analysis
Multi Trace Analysis
You can load up to four waveforms that have been measured on the instrument and display
them simultaneously for comparison. You can adjust the vertical display position of each loaded
waveform.
Trace 1
Trace 2
Trace 3
Trace 4
Displays up to four waveforms simultaneously
You can move a waveform over another waveform to compare the two.
1.7 Application