U2
Fault Trace
U2-01 Existing detected fault
-
-
-
Q
U2-02 Previous detected fault
-
-
-
Q
U2-03 Frequency reference when fault was detected
%
-
-
Q
U2-04 Output frequency when fault was detected
Hz
-
-
Q
U2-05 Output current when fault was detected
A
-
-
Q
U2-06 Motor speed reference
%
-
-
Q
U2-07 Output voltage when fault was detected
V
ac
-
-
Q
U2-08 DC bus voltage
V
dc
-
-
Q
U2-09 Output power
kW
-
-
Q
U2-10 Torque reference at fault
%
-
-
Q
U2-11 Input terminal status
-
-
-
Q
U2-12 Output terminal status
-
-
-
Q
U2-13 Drive status before fault was detected
-
-
-
Q
U2-14 Elapsed time since fault was detected
H
-
-
Q
U2-15 Motor magnetizing current (I
q
) at fault
%
-
-
B
U2-16 Motor magnetizing current (I
d
) at fault
%
-
-
B
U2-17 Internal control status 2 at fault
-
-
-
A
U2-18 Command 1 from option at fault
-
-
-
A
U2-19 Command 2 from option at fault
-
-
-
A
U2-20 External torque reference at fault
%
-
-
A
U2-21 Torque compensation at fault
%
-
-
A
U2-22 Speed controller ASR output at fault
-
-
-
A
U3
Fault History
U3-01 Most recent fault code
-
-
-
Q
U3-02 2nd most recent fault code
-
-
-
Q
U3-03 3rd most recent fault code
-
-
-
Q
U3-04 4th most recent fault code
-
-
-
Q
U3-05 Elapsed time since most recent fault
H
-
-
Q
U3-06 Elapsed time since 2nd most recent fault
H
-
-
Q
U3-07 Elapsed time since 3rd most recent fault
H
-
-
Q
U3-08 Elapsed time since 4th most recent fault
H
-
-
Q
Initialization
A
Initialization
A1
Initialization Set-up
A1-01 Parameter access level
0: Operation only
3: Basic level
1: User program
4: Advanced level
2: Quick start level
-
0~4
2
Q
A1-03 Operator status
0: No initialization
3330: 3-Wire initialization
2220: 2-Wire initialization
-
0~9999
0
Q
A1-04 Password entry
-
0000~9999
-
Q
No.
Parameter Description
Unit
Setting Range
Default
Access
Level
User
Setting
Appendix
VS-616PS5 Parameter List