VS-616PS5 Programming Manual
61
H
Control Circuit Terminal Parameters
H1
Digital Inputs
The VS-616PS5 has six multi-function contact inputs for the set-up of numerous func-
tions, including multi-step speed operation, PID, speed search, speed/torque control
selection, and many others. This section includes descriptions of these functions.
The following table lists the function selections for the multi-function contact inputs
(terminals 3 to 8), and lists the reference page that provides a more detailed explana-
tion of each.
• Three-wire Control (setting: “0”)
Enable 3-wire control when
H1-01
is set to “0”. The terminal set to “0” becomes the
FWD/REV run command.
H1-01 Multi-function Input Terminal 3 Selection
B
H1-02 Multi-function Input Terminal 4 Selection
B
H1-03 Multi-function Input Terminal 5 Selection
B
H1-04 Multi-function Input Terminal 6 Selection
B
H1-05 Multi-function Input Terminal 7 Selection
B
H1-06 Multi-function Input Terminal 8 Selection
B
Setting
Function
Reference Page
0
3-Wire Control
62
1
Local/Remote Selection
62
2
Option/Inverter Selection
62
3
Multi-Step Ref. 1
(factory default, H1-03)
35
4
Multi-Step Ref. 2
(factory default, H1-04)
35
5
Multi-Step Reference 3
35
6
Jog Speed Ref.
(factory default, H1-05)
35
7
Multi-Accel/Decel 1
24
8
External Baseblock N.O.
(factory default H1-06)
62
9
External Baseblock N.C.
62
A
Accel/Decel Hold Command
63
B
Inverter Overheat OH2 Alarm
63
C
Multi-function Analog Input Enable/Disable
63
E
Speed Control Integral Value Reset
63
10
Up Command
63
11
Down Command
63
12
Forward Jog
64
13
Reverse Jog
64
14
Fault Reset
(factory default, H1-02)
65
15
Fast-Stop
25
18
Timer Function
17
19
PID Disable
19
1A
Multi-Accel/Decel 2
24
1B
Program Lockout
65
1E
Analog Reference Sample/Hold Selection
65
1F
Terminal 13/14 Selection
65
24
External Fault
(factory default H1-01)
65
71
Speed/Torque Control Change
40
77
ASR Gain Switch
29
Section H: Control Circuit Terminal Parameters
H1 Digital Inputs