VS-616PS5 Programming Manual
95
O
Operator Parameters
O1
Monitor Selection
The operation menu allows simple viewing of four monitor variables (via the DSPL
key). These are Speed ref, Speed out, I
out
, and a user-selected monitor. Using the
table below, set this parameter to the setting corresponding to the monitor item
desired for the fourth (user monitor) selection.
O1-01
User Monitor Selection
B
Setting
Description
5
Motor speed
6
Output voltage
(factory default)
7
DC bus voltage
8
Output power
9
Torque reference (internal)
15
Terminal 13 input voltage level
16
Terminal 14 input voltage or current level
17
Terminal 16 input voltage level
18
Motor secondary current (Iq)
19
Motor excitation current (Id)
20
SFS output frequency
21
ASR input
22
ASR output
27
Voltage reference (Vd output)
28
CPU ID number
29
Voltage limit control output
30
qAxis current control output
31
dAxis current control output
32
Output voltage reference (Vq)
33
Output voltage reference (Vd)
41
LED check
42
Internal control status 2
43
Command 1 from option
44
Command 2 from option
45
External torque reference
46
Torque compensation value
47
DO-08H output status
48
Momentary power loss decrease capacity
49
Control section software number
50
Speed detection PG counter value
51
PID feedback
52
DI-16H input status
Section O: Operator Parameters
O1 Monitor Selection