89
Alarm reset /ALM-RST
5-11-2. /WARN
Set the warn output threshold. When the motor speed is larger than the threshold, output /WARN.
P3-19
Forward warn speed
Unit
Default setting
Range
Suitable
mode
Change
Effective
1rpm
Related
to
the
motor
0~10000
All
Servo
OFF
At once
P3-20
Reverse warn speed
Unit
Default setting
Range
Suitable
mode
Change
Effective
1rpm
Related
to
the
motor
0~10000
All
Servo
OFF
At once
5-11-3. Rotation checking (/TGON)
(1) Signal setting
(2) Parameter setting
Parameter
Signal
Type
Default
Suitable
mode
Modify
Effective
P5-47
/ALM
Output
n.0002
All
Any
At once
Output always open signal from SO2
Parameter
Signal
Type Default
Meaning
Modify Effective
P5-24
/ALM-RST
Input
n.0002
Input always open
signal from SI2
Any
At once
1.
Find the alarm reason and fix it, then clear the alarm via this signal.
2.
/ALM-RST can be distributed to input terminal via this parameter. As the alarm signal is
related to the safe running of servo, /ALM-RST signal cannot be set to always effective.
(n.0010);
3.
The alarm related to encoder such as E-013□ (0, 1, 2), E-014□ (0, 1, 2) cannot be reset via
/ALM-RST.
4.
The range is 0000-0015. /ALM-RST can be distributed to input terminal via parameter
P5-24.
Parameter
Signal
Type
Default
Meaning
Range
P5-45
/WARN
Output
n.0000
Warning output
0000-0013
When the warning happens, servo will not be forced OFF but output the warning.
/WARN can be distributed to input terminal via parameter P5-45.
Parameter
Signal
Type
Default
Suitable mode
Modify
Effective
P5-40
/TGON
Output
n.0000
All
Any
At once
1.
The servo will be considered in the rotation when the servo motor speed is higher than P5-03.
2.
The range is 0000-0013. /TGON can be distributed to output terminal via parameter P5-40, refer to
chapter 5-12-3.
P5-03
Internal torque command setting
Unit
Default
Range
Suitable mode
Modify
Effective
1rpm
50
1~10000
All the modes
Servo OFF
Immediately
Set the range of rotation checking output. If servo motor speed is up to P5-03, the servo motor is
considered to be running and output rotation checking signal (/TGON).
There is default 10rpm hysteresis loop, please refer to chapter 5-11-4.