33
n.x□xx
Stop bit
2
0
:
2 bits, 2
:
1 bit
Servo OFF
n.□xxx
Parity bit
2
0
~
2
0:no parity, 1: odd parity, 2: even
parity
Servo OFF
Note: data bit cannot be changed, it is 8 bits.
RS-485 port
DS3E series
CN1: port definition at drive
side
No.
Name
CN1-2
A
CN1-3
B
1.
The fieldbus module is necessary to connect to CN1 to
perform X-NET fieldbus function. The module cannot
hot plug. Please use Profibus cable to ensure the
communication reliability.
2.
For Modbus-RTU communication.
Note: DS3L cannot support RS485 and fieldbus.
Communication parameters:
RS485 default communication parameters: baud rate 19200bps, data bit 8, stop bit 1, even parity,
Modbus station no.1.
The Modbus station no. can be set through P7-00:
Parameter
Function
Default value
Range
Effective time
P7-00
Modbus station no.
1
0
~
255
Servo OFF
The communication parameters can be set through P7-01:
Parameter
Function
Default value
Range
Effective
time
n.xx□□
Baud rate
06
00
~
10
00
:
300
01
:
600
02
:
1200
03
:
2400
04
:
4800
05
:
9600
06
:
19200
07
:
38400
08
:
57600
09
:
115200
0A
:
192000
0B
:
256000
0C
:
288000
0D
:
384000
0E
:
512000
0F
:
576000
10
:
768000
11
:
1M
12
:
2M
13
:
3M
14
:
4M
15
:
5M
16
:
6M
Servo OFF
n.x□xx
Stop bit
2
0
:
2 bits, 2
:
1 bit
Servo OFF
1
5 9
6