103
Signal setting:
Related parameter setting:
P4-00
n.xxx□
The quantity pass the Z phase signal after leaving the limit switch
Unit
Default
Range
Suitable
mode
Modify
Effective
1
2
1~F
5, 6
Servo OFF
Immediately
P4-01
The speed hitting the proximity switch
Unit
Default
Range
Suitable
mode
Modify
Effective
0.1rpm
600
0~50000
5, 6
Servo OFF
Immediately
P4-02
The speed leaving the proximity switch
Unit
Default
Range
Suitable
mode
Modify
Effective
0.1rpm
100
0~50000
5, 6
Servo OFF
Immediately
Detailed explanation:
Find reference origin diagram:
Parameter
Signal
Default
Meaning
Modify
P5-28
/SPD-A
n.0000
Mode 3: internal speed
selecting signal
Range: 0000-0014, distributes to
input terminal through P5-28.
When it set to 0001, it means
input signal from SI1.
Mode 5/6: find origin point
at forward direction
P5-29
/SPD-B
n.0000
Mode 3: internal speed
selecting signal
Range: 0000-0014, distributes to
input terminal through P5-29.
When it set to 0001, it means
input signal from SI1.
Mode 5/6: find origin point
at forward direction
/P-OT
/N-OT
Speed P4-01
Direction CW
Stop mode
P0-28
Speed P4-02
Direction CCW
P4-00
Speed P4-01
Direction CCW
Stop mode
P0-28
Speed P4-02
Direction CW
P4-00
Reference origin
of forward side
Reference origin
of reverse side
Z signal quantity
Z signal quantity
①
②
③