THIS DOCUMENT IS THE PROPERTY OF XICOM TECHNOLOGY. REPRODUCTION OR RELEASE WITHOUT EXPRESS PERMISSION IS STRICTLY PROHIBITED.
XTS-200C, 5.85-6.425GHz, W/BUC
Document No. 305-0281-002
REV B
Page 8 of 8
Appendix A
(cont.)
Requirements
Spec
Paragraph
No
Test Description
Test Condition
Min Max
Units
Measured
Performance
Pass
or
Fail
3.2.5.1 Gain
Small
Signal
Note 2)
Input Power P
in
to provide
P
out
=P
rated
-10 dB
at midband
Freq = 6.1375 GHz
STD
Output freq swept
from 5.85 to 6.425 GHz
65
75
dB
See attached
plot
Pass
Fail
3.2.5.2
Gain Flatness over
575MHz
Note 2)
STD
Output freq swept
from 5.85 to 6.425 GHz
N/A 2
.5
dB
See attached
plot
Pass
Fail
3.2.5.3
Gain Flatness over 40 MHz
Note 2)
STD
Output freq swept
from 5.85 to 6.425 GHz
N/A 1.0 dB
See attached plot
Pass
Fail
3.2.5.4 Gain
Slope
Note 2)
STD
Output freq swept
from 5.85 to 6.425 GHz
NA ±
0.04
dB/MHz
See attached plot
Pass
Fail
3.2.5.5 Gain
Control
Note 2) and Set Attn to 20 dB
STD
Output freq swept
from 5.85 to 6.425 GHz
20
N/A
dB
Pass
Fail
See attached plot
3.2.16 Spurious
Signals
(Inband discrete) maximum
Note 2)
Adjust P
in
for P
rated
-3 dB
STD
P
out
= P
rated
-3dB
30 Hz to 10 kHz
10 kHz to 500 kHz
> 500 kHz
-37
-20(1.5+log(f))
-
13
-72
dBc
dBc
dBc
Span = 2 kHz
Span = 20 kHz
Span = 200kHz
Span = 2 MHz
Span = 20 MHz
Span = 200 MHz
Pass
Fail
NA
1600
VA
Pass
Fail
STD
VAC= 90 , 60 Hz
P
out
= P
rated
0.95
N/A
Pass
Fail
NA
1600
VA
Pass
Fail
3.2.19
Prime Power
Power Factor
5min after turn on
STD
VAC= 264 , 60 Hz
P
out
= P
rated
0.95
N/A
Pass
Fail
STD
Set drive level for 0 dBm
at sample port.
Record output power at
flange for freq below :
Record Output
Power
(Coupling
Factor)
Freq = 5.85 GHz
N/A N/A dB
Freq = 6.1375 GHz
N/A N/A dB
3.2.18
Sample Port Coupling
Freq = 6.425 GHz
N/A N/A dB
Tested by : _______________ Date:________ Verified by : ________________
Date: _______
Summary of Contents for XTS-200C
Page 10: ...MNC 0000 010 2 Revision A6...
Page 38: ...MNC 0200 004 14 of 14 Revision C Safety Sicherheit...
Page 64: ...MNC 0300 011 26 of 26 Revision H Unpacking and Installation...
Page 72: ...Operation MNC 0400 012 8 of 8 Revision C...
Page 104: ...MNC 0500 010 32 Revision D Solid State Power Amplifier Communication and Protocol...
Page 122: ...MNC 0700 001 6 Revision F Service and Repair...
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 144: ...MNC 0000 039 4 of 12 Revision 2 ODU SSPA Power Supply Removal...
Page 152: ...MNC 0000 039 12 of 12 Revision 2 ODU SSPA Power Supply Removal...
Page 155: ...MNC 0000 003 3 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Page 156: ...MNC 0000 003 4 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Page 160: ...MNC 0000 002 4 Revision A Protocol Adendum Block Upconverter...