MNC-0500-010
30
Revision D
Solid State Power Amplifier Communication and Protocol
Miscellaneous Setup
Command Byte
: 'P'
Function
: Miscellaneous Setup
Parameters:
“CX” to set Configuration Mode.
X is the redundancy mode you wish to operate.
0 — is single thread no waveguide switch.
1 — is redundant system with one waveguide switch (1:1 configuration.)
2 — is power combined system with two waveguide switches (1+1 configuration.)
3 — is redundant system with a load switch on the output (1:1 w/load.)
4 — Reserved
Parameters:
IX to enable and disable Gain Temperature Compensation. X = 0 to
disable; X = 1 to enable.
Parameter:
JXX to set ambient room temperature in degrees C. XX = 20 to 60 °C
Parameter:
EX
X is the Ethernet mode or parameter you wish to set.
D = Bring interface Down (disable.)
U = Bring iinterface Up (enable.)
Waveguide Switch Control
Command Byte:
‘U’
Format:
‘U3’ Activate override mode and switch in Amplifier Switch 2.
‘U2’ Activate override mode and switch in other Amplifier Switch 2.
‘U1’ Activate override mode and switch in Amplifier Switch 1.
‘U0’ Activate override mode and switch in other Amplifier Switch 1.
‘UM’ Activate overide mode.
‘UA’ Terminate overide mode, activating automatic mode.
Notes: When sending a ‘U3‘, ‘U2’, ‘U1’ or ‘U0’ command, also send a ‘UM’ command
to the other amplifier to prevent unwanted automatic-mode switches.
Compatibility:
For Redundant ODUs only
Summary of Contents for XTS-200C
Page 10: ...MNC 0000 010 2 Revision A6...
Page 38: ...MNC 0200 004 14 of 14 Revision C Safety Sicherheit...
Page 64: ...MNC 0300 011 26 of 26 Revision H Unpacking and Installation...
Page 72: ...Operation MNC 0400 012 8 of 8 Revision C...
Page 104: ...MNC 0500 010 32 Revision D Solid State Power Amplifier Communication and Protocol...
Page 122: ...MNC 0700 001 6 Revision F Service and Repair...
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 144: ...MNC 0000 039 4 of 12 Revision 2 ODU SSPA Power Supply Removal...
Page 152: ...MNC 0000 039 12 of 12 Revision 2 ODU SSPA Power Supply Removal...
Page 155: ...MNC 0000 003 3 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Page 156: ...MNC 0000 003 4 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Page 160: ...MNC 0000 002 4 Revision A Protocol Adendum Block Upconverter...