MNC-0500-010
24
Revision D
Solid State Power Amplifier Communication and Protocol
Get Serial Configuration
Command Byte
: 'X'
Parameters
: '?' returns the configuration of the communications port that the query
was received on. "1?" returns information on COM1. "2?" returns information on
COM2. “R?” returns RS-485 Configuration.
Response for ‘?’, ‘1?’, and ‘2?’
: "CBBBBBBPDS"
C Communications port; 1=COM1, 2=COM2 (COM1 = RS-232 port, COM2 = RS-
485 port.)
BBBBBB Current baud rate. Example: 019200.
P Parity, 'N', 'O', or 'E'.
D Data bits, '8' or '7'.
S Stop bits, '1'
Response for ‘R?’
: "ABC"
A A is 4 or 2 Wire
B B is T (Terminated) or U (Unterminated)
C C is RS 485 address
Compatibility
: Not available when talking to an amplifier via a Digital Outdoor
Controller.
Notes
: See also the
Set Serial Configuration
command.
Summary of Contents for XTS-200C
Page 10: ...MNC 0000 010 2 Revision A6...
Page 38: ...MNC 0200 004 14 of 14 Revision C Safety Sicherheit...
Page 64: ...MNC 0300 011 26 of 26 Revision H Unpacking and Installation...
Page 72: ...Operation MNC 0400 012 8 of 8 Revision C...
Page 104: ...MNC 0500 010 32 Revision D Solid State Power Amplifier Communication and Protocol...
Page 122: ...MNC 0700 001 6 Revision F Service and Repair...
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 144: ...MNC 0000 039 4 of 12 Revision 2 ODU SSPA Power Supply Removal...
Page 152: ...MNC 0000 039 12 of 12 Revision 2 ODU SSPA Power Supply Removal...
Page 155: ...MNC 0000 003 3 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Page 156: ...MNC 0000 003 4 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Page 160: ...MNC 0000 002 4 Revision A Protocol Adendum Block Upconverter...