Operation
MNC-0400-012
7 of 8
Revision C
Vorsicht
Überschreiten Sie nicht die in der Produktspezifikation
angegebene Begrenzung der HF-Eingangsspannung. Sie
verursachen sonst eine Überhitzung der SSPA.
Nichtbeachtung kann zu einer bleibenden Schädigung der
SSPA führen.
Turn On
1 There are two ways to turn ON the SSPA:
Normal (M&C) Interface) — When operating the SSPA with the standard digital
M&C Interface the system turns ON as soon as prime AC power is applied. The
main voltage is turned ON by sending the appropriate command through the sys-
tem interface. Refer to the chapter titled
SSPA Communication and Protocol
for
command details.
Manual — In manual configuration the SSPA will turn ON the control system as
soon as prime AC power is applied. The control system is held in the reset mode
until the J1-Pin h is connected to either
J1-Pin Z or J1-Pin a. This allows the control system to operate normally.
Note
In manual operation the system is configured to transmit ON when the
prime AC power is on.
2. Connect and turn ON a test RF signal source. Slowly increase the
drive power to the amplifier. Monitor the RF output power through
the SSPA’s built-in sampler or through an external coupler.
Turn Off
There are two shut down modes.
Transmit OFF (M&C Interface)
When operating the SSPA with the standard digital M&C Interface the
main system voltage is turned OFF by sending the appropriate command
through the system interface. Refer to the chapter titled
SSPA Communication
and Protocol
for command details.
System OFF (Manual)
The SSPA is switched off by disconnecting or manually turning
OFF the prime AC power. If you turn the system OFF manually
it will turn ON and be in the same state as it was when you
turned it off.
Summary of Contents for XTS-200C
Page 10: ...MNC 0000 010 2 Revision A6...
Page 38: ...MNC 0200 004 14 of 14 Revision C Safety Sicherheit...
Page 64: ...MNC 0300 011 26 of 26 Revision H Unpacking and Installation...
Page 72: ...Operation MNC 0400 012 8 of 8 Revision C...
Page 104: ...MNC 0500 010 32 Revision D Solid State Power Amplifier Communication and Protocol...
Page 122: ...MNC 0700 001 6 Revision F Service and Repair...
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 144: ...MNC 0000 039 4 of 12 Revision 2 ODU SSPA Power Supply Removal...
Page 152: ...MNC 0000 039 12 of 12 Revision 2 ODU SSPA Power Supply Removal...
Page 155: ...MNC 0000 003 3 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Page 156: ...MNC 0000 003 4 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Page 160: ...MNC 0000 002 4 Revision A Protocol Adendum Block Upconverter...