Unpacking and Installation
Sum Fault Input
Refer to Figure 13. The Sum Fault input comes from the other amplifier.
The Sum Fault input provides a pull up resistor of 100K to + 15V for an
open collector input at J6-M. A logic HI is present when the other
amplifier faults or is turned off.
Figure 13, Sum Fault Input
Sum Fault Output
Refer to Figure 14. The Sum Fault output is an open collector output at
J6-L. The output transistor will be off when this amplifier faults or is turned
off.
Figure 14, Sum Fault Output