MNC-0300-011
9 of 26
Revision H
Unpacking and Installation
Power and Interface Interconnections
When performing the procedures in this section refer to the Wiring and
Interconnect Drawings for your specific amplifier. These drawings are
located in the appendix titled
Interconnect Drawings
.
Prime Power Connections
The AC Prime Power receptacle is located on the amplifier front panel.
Nominal line voltage is 100 to 260 VAC (180 to 260 VAC on some high
power units), 47-63 Hz, single phase. The amplifier will operate when the
AC line voltage is anywhere in the specified range. Figure 3 shows the
pinouts for a low power ODU.
Figure 3, Connector J2 Pinout for Low Power Unit
Refer to the Outline Drawing in the appendix titled
Mechanical Drawings
.
Prime Power Enable Switch
The prime power to the amplifier can be either enabled or disabled
depending on the position of the Prime Power Enable Switch. When the
switch is closed it disables the bias voltage of the PFC which turns on the
DC supply. When the switch is opened a soft start circuit is enabled which
limits the turn on surge current into the supply. A low line protection circuit
shuts the power supply down upon detection of a DC supply output under
voltage fault.
Summary of Contents for XTS-200C
Page 10: ...MNC 0000 010 2 Revision A6...
Page 38: ...MNC 0200 004 14 of 14 Revision C Safety Sicherheit...
Page 64: ...MNC 0300 011 26 of 26 Revision H Unpacking and Installation...
Page 72: ...Operation MNC 0400 012 8 of 8 Revision C...
Page 104: ...MNC 0500 010 32 Revision D Solid State Power Amplifier Communication and Protocol...
Page 122: ...MNC 0700 001 6 Revision F Service and Repair...
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 144: ...MNC 0000 039 4 of 12 Revision 2 ODU SSPA Power Supply Removal...
Page 152: ...MNC 0000 039 12 of 12 Revision 2 ODU SSPA Power Supply Removal...
Page 155: ...MNC 0000 003 3 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Page 156: ...MNC 0000 003 4 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Page 160: ...MNC 0000 002 4 Revision A Protocol Adendum Block Upconverter...