THIS DOCUMENT IS THE PROPERTY OF XICOM TECHNOLOGY. REPRODUCTION OR RELEASE WITHOUT EXPRESS PERMISSION IS STRICTLY PROHIBITED.
XTS-200C, 5.85-6.425GHz, W/BUC
Document No. 305-0281-002
REV B
Page 7 of 8
Appendix A
ATP Test Performance Sheet
Serial Number _____________________
Test Conditions :
Unless otherwise specified, data will be taken
at “ Standard Conditions” aka STD defined as room
(ambient) temperature (nominal 25deg C) , 120V AC , 60Hz
line voltage and attenuation setting =0 dB.
Test Step 1: Test SSPA per the Final Test Setup Procedure WI-0070-01. Attach results to this TPS form
Test Step 2: Test the SSPA per the following:
Requirements
Spec
Paragraph
No
Test Description
Test Condition
Min Max
Units
Measured
Performance
Pass
or
Fail
3.2.1
Frequency Translation
Frequency (Fout)
Fout=4.9GHz+IF
Fout= 5.85GHz
6.00GHz
6.1275GHz
6.425GHz
Note 1):
Output frequency(Fout)= Local
Oscillator (LO)+Input
Frequency(IF)
Fin(MHz) LO(GHz) Fout(GHz)
950 4.9 5.85
1100 4.9 6.00
1237.5 4.9 6.1375
1525 4.9 6.425
STD
Spectrum analyzer
span=5kHz
Input frequency
reference = 10 MHz
after 15min turn on
Record Fout with IF=
950 MHz
1100 MHz
1237.5 MHz
1525 MHz
Fout-0.5
Fout-0.5
Fout-0.5
Fout-0.5
Fout+0.5
Fout+0.5
Fout+0.5
Fout+0.5
kHz
kHz
kHz
kHz
Pass
Fail
3.2.3
Output power P1 dB
STD
Freq= 5.85, 6.425 GHz
Swept Input Power from
-35 dBm to
–12 dBm
52
N/A
dBm
See attached
plots
Pass
Fail
3.2.3.1
Reverse Power Protection
STD
Freq = 6.1375 GHz
Operating into a short
P
rated
–
6.5
P
rated
–
5.5
dBm
Pass
Fail
Summary of Contents for XTS-200C
Page 10: ...MNC 0000 010 2 Revision A6...
Page 38: ...MNC 0200 004 14 of 14 Revision C Safety Sicherheit...
Page 64: ...MNC 0300 011 26 of 26 Revision H Unpacking and Installation...
Page 72: ...Operation MNC 0400 012 8 of 8 Revision C...
Page 104: ...MNC 0500 010 32 Revision D Solid State Power Amplifier Communication and Protocol...
Page 122: ...MNC 0700 001 6 Revision F Service and Repair...
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 144: ...MNC 0000 039 4 of 12 Revision 2 ODU SSPA Power Supply Removal...
Page 152: ...MNC 0000 039 12 of 12 Revision 2 ODU SSPA Power Supply Removal...
Page 155: ...MNC 0000 003 3 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Page 156: ...MNC 0000 003 4 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Page 160: ...MNC 0000 002 4 Revision A Protocol Adendum Block Upconverter...