Before Using the Machine
1
57
1.10 Calibrating the Scan Sensor Gap
1.10
Calibrating the Scan Sensor Gap
Environmental variations such as temperature and humidity may affect the positioning of each scanning sensors,
and this can result in gaps at joints between adjacent sensors.
In such a case, you can calibrate the gaps using functions under [Scan Sensor Gap Calibration].
1.10.1
Performing Auto Adjustment
Use these steps to automatically adjust the gaps by using the calibration chart that came with the machine.
Steps
St
1.
Press [Scan Sensor Gap Calibration] on the [Services Home] screen.
2.
Press [Auto Adjust].
3.
Load the calibration chart face down on the document
table, and press the <Start> button on the control panel.
The gaps between the scanning sensors are automatically
calibrated.
Note
After auto calibration has completed, check the
calibration result by using your documents.
If auto calibration has failed with an error, take
corrective actions according to the error code,
and perform auto calibration again. For more
information on error codes, refer to "Error Code"
(p. 61).
Summary of Contents for Wide Format 6705 System
Page 1: ...Xerox Wide Format 6705 System User Guide...
Page 4: ...Preface 4...
Page 76: ...1 Before Using the Machine 1 16 Media Types 76...
Page 162: ...3 Scan 3 12 Scan Filing Options Screen 162...
Page 214: ...6 Con guration 6 3 Scanner Environment Settings 214...
Page 280: ...8 Problem Solving 8 12 Finding More 280...
Page 295: ...System Settings 9 295 9 3 Common Service Settings Steps...
Page 342: ...9 System Settings 9 9 Authentication Security Settings 342...