36
64.1168.0790 I 002
EN
Operating Instructions
Operating Instructions
9. Eliminating malfunctions
/ In the event of a malfunction, always remove
the pressure cooker from the hob.
/
Never open the pressure cooker with force!
Malfunctions
Cause
Remedy
Cooking time is too long
or the cooking signal does
not rise
Diameter of the hob is not
suitable
Select a hob that fits the diameter of the pot
Energy level unsuitable
Set at highest energy level
a) The lid is not sitting on the
pot properly.
b) The double seal is missing.
c) The lid is not assembled
correctly.
1. Completely release the pressure from the pot as described
in
Chapter 6.6
and open it.
2. Check seal ring
L
/ double seal
I
(see Image J)
to
ensure they are correctly in place.
3. Check lid
6
for correct fit / assembly.
4. Close the pot as described in
Chapter 5.3
.
The ball in the safety valve /
automatic cooking system is
not in the right place
1. Completely release the pressure from the pot as described
in
Chapter 6.6
and open it.
2. Remove lid handle
B
as described in
Chapter 5.1
.
3. Check the position of the metal ball in the safety valve
7
and clean if necessary.
4. Close the pot as described in
Chapter 5.3
.
Not enough liquid
1. Completely release the pressure from the pot as described
in
Chapter 6.6
and open it.
2. Refill liquid (at least 1/4 l).
3. Close the pot as described in
Chapter 5.3
.
Steam is escaping from
the lid
Seal ring and / or pot rim is
not clean
1. Completely release the pressure from the pot as described
in
Chapter 6.6
and open it.
2. Clean seal ring
L
and pot rim.
3. Close the pot again as described in
Chapter 5.3
.
Knob is not at Cooking Level 1 or 2. Set knob
C
to Cooking Level 1 or 2.
Seal ring damaged or hard
(due to wear)
Replace the seal ring
L
with an original WMF seal ring.
Double seal does not fit
properly or is damaged.
Correct the position of the double seal
I
or replace with
original WMF replacement part.
Summary of Contents for 3201005794
Page 1: ...Perfect Premium Perfect Excellence Bedienungsanleitung User Manual ...
Page 4: ...E F G H ...
Page 5: ...1 1 2 Click ...
Page 6: ...I Doppeldichtung wechseln I Changing the double seal J Innenskalierung I Inside scaling ...
Page 484: ...TH คู มือการใช งาน 478 64 1168 0790 I 002 ...
Page 525: ......