Explanation of Function
Seite 60 / 180
Adjustable time
The acceleration and deceleration time can be set.
Set a long time to accelerate or decelerate slowly or set a short
time to accelerate or decelerate quickly.
The time setting is the time it takes to accelerate from zero to the
maximum frequency and to decelerate from the maximum
frequency to zero.
When select the LAD cancel (LAC) function to intelligent input and turn on the signal
acceleration/deceleration time is disregarded and the output frequency flatters the command frequency
instantaneously.
Set item
Function
code
Limit of
setting
Contents
Acceleration
time
F002/F20
2/F302
0.01-3600
.
Unit : second
Setting acceleration time from zero to
maximum frequency.
Deceleration
time
F003/F20
3/F303
0.01-3600
.
Unit : second
Setting deceleration time from maximum
frequency to zero.
Intelligent
input
selection
C001-C00
8
46 LAD
cancel
However short you set the adjustable time, the adjustable time of the actual motor can’t be shorter than the
shortest
adjustable time determined by the inertial Effect J of the mechanical system and motor torque.
If you set the time shorter than the shortest adjustable time, a protection trip of OC or OV may occur.
F002/F202/F302: 1
st
/ 2
nd
/ 3
rd
Acceleration time
F003/F203/F303: 1
st
/2
nd
/3
rd
Deceleration time
C001-C008: Intelligent input selection
Relation
Output frequency setting
Output frequency
Maximu
m
frequen
Actual
accelerat
F002/F202/F302
Actual
decelerat
F003/F203/F303