Explanation of Function
Seite 158 / 180
(ix) 08 command: This returns each set value to initial value.
This works in conjunction with initial selection (b084). If b084 is 00, the trip history is cleared.
Transmission frame
Frame format
Explanation
Data size
Value
STX
Control code(Start of TeXt)
1 byte
STX (0x02)
Cord
Station number of inverter
2 byte
01-32, FF(all code communication)
Comman
d
Transmission command
2 byte
08
BCC
Block check code
2 byte
Exclusive OR of Code, Command and
Data
(5) Reference
CR Control
code(Carriage
Return)
1 byte
CR (0x0D)
Replay frame
On normal reply : (4) - (i) Reference
On abnormal reply : (4) - (ii) Reference
(x) 09 command: This checks whether it is possible to store set value to EEPROM or not.
Transmission frame
Frame format
Explanation
Data size
Value
STX
Control code(Start of TeXt)
1 byte
STX (0x02)
Code
Station number of inverter
2 byte
01-32
Comman
d
Transmission command
2 byte
09
BCC
Block check code
2 byte
Exclusive OR of Code, Command and
Data
(5) Reference
CR Control
code(Carriage
Return)
1 byte
CR (0x0D)
Transmission frame
Frame format
Explanation
Data size Value
STX
Control code(Start of TeXt)
1 byte
STX (0x02)
Code
Station number of inverter
2 byte
01-32
ACK
Control code(Acknowledge) 1 byte
ACK (0x06)
Data
Data
2 byte
Allowance with 01
BCC
Block check code
2 byte
Exclusive OR of Code, Command and
Data
(5) Reference
CR Control
code(Carriage 1 byte
CR (0x0D)
STX Code
Comman
d
BCC CR
STX Code
Comman
d
BCC CR
STX Code ACK
Data BCC CR