Explanation of Function
Seite 155 / 180
Code Status
00
On stopping
01
On running
02 On
tripping
(vi) 05 command: This reads trip history data.
Transmission frame
Frame format
Replay frame
Frame format:
(Note8) The monitor data (trip history) on trip memorizes the last six errors with an accumulated count
number (8byte).
_ _ _
STX Code
Comman
d
BCC CR
Explanation
Data size Value
STX
Control code(Start of TeXt)
1 byte
STX (0x02)
Cord
Station number of inverter
2 byte
01-32
Command Transmission command
2 byte
05
BCC
Block check code
2 byte
Exclusive OR of Code, Command and
Data
(5) Reference
CR Control
code(Carriage
Return)
1 byte
CR (0x0D)
STX Code
Data
BCC CR
Explanation
Data size Value
STX
Control code(Start of TeXt)
1 byte
STX (0x02)
Code
Station number of inverter
2 byte
01-32
Data
Each monitor data on trip
440 byte
(Note8) reference
BCC
Block check code
2 byte
Exclusive OR of Code, Command and
Data
(5) Reference
CR
Control code(Carriage Return) 1 byte
CR (0x0D)
Accumulated
count number
Trip history 1
Trip history 6
Monitor item
Units Magnif
ication
Data
size
Notes
Trip factor
-
-
8byte
Inverter status A)
-
-
8byte
Inverter status B)
-
-
8byte
Inverter status C)
-
-
8byte
Output frequency
Hz
x10
8byte
Tenth ASCII code
Accumulated RUN
time
hour
x 1
8byte
Tenth ASCII code
Output current
A
x10
8byte
Tenth ASCII code
Current voltage
V
x10
8byte
Tenth ASCII code
Power source ON time
hour
x1
8byte
Tenth ASCII code
U
pp
er
L
ow
er