wc_tx001903gb.fm
43
E 1100
Operation
4.10
Refueling the Machine
Requirements
Machine shut down
Machine level with the ground
Diesel fuel supply
Procedure
Perform the procedure below to refuel the machine.
Note:
On models with generators, it is not necessary to fill the generator’s fuel
tank. Both the burner and the generator use the machine’s fuel tank.
1. Lift the lever
(a)
on the fuel cap.
2. Rotate the lever counterclockwise until it stops.
3. Remove the fuel cap from the tank.
4. Fill the tank with the appropriate grade of fuel for the weather conditions until the
gauge
(b)
reads full. Leave room within the tank for possible fuel expansion.
5. Reinstall the fuel cap.
wc_gr008446
a
wc_gr008447
wc_gr008448
b
wc_gr008721
CAUTION
Fire and health hazard. Fuel expands when heated. Expanding fuel in a overly-full
tank can lead to spills and leaks.
f
Do not overfill the fuel tank.
Summary of Contents for 5000620172
Page 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes ...
Page 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588 ...
Page 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance ...
Page 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706 ...
Page 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller ...
Page 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller ...
Page 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit ...
Page 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662 ...
Page 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit ...
Page 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram ...
Page 160: ......
Page 161: ......