Using Heat Exchangers (to Heat Air)
Background
The standard E 1100 can be combined with Wacker Neuson Heat Exchangers
(HX 50 and HX 100) and Single (SPP) and Dual Pump Packs (DPP) to convert the
heating application from surface to air. The typical configurations are shown below;
however, this does not represent all possible configurations. For more information,
contact Wacker Neuson Application Support.
Configuration
requirements
In order to connect Heat Exchangers to the machine, additional accessories are
required to support the additional load on the machine’s systems.
NOTICE:
Use caution when adding accessories; failure to adhere to these
requirements will damage your machine.
For more information regarding setup and connection of these configurations,
continue reading.
Heat Exchanger Model
Max.
Qty.
Additional components required for maximum
quantity of Heat Exchangers
1-2 Adapter
2-1 Adapter
HX 50
2
--
--
HX 100
1
1
1
Summary of Contents for 5000620172
Page 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes ...
Page 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588 ...
Page 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance ...
Page 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706 ...
Page 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller ...
Page 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller ...
Page 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit ...
Page 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662 ...
Page 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit ...
Page 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram ...
Page 160: ......
Page 161: ......