Troubleshooting
E 1100
118
ghi_tx001154gb.fm
Thaw progress is below
capacity.
The insulation is insuffi-
cient.
Add additional insulation
blankets.
The moisture is insufficient.
Verify that there is standing
water on job site.
There is no vapor barrier.
Lay down vapor barrier.
The HTF is not flowing.
Verify that the pump pres-
sure is nominal and hoses
are not restricted.
The temperature control is
not set properly.
Set the temperature control
to optimum setting. This
setting depends on environ-
mental conditions at the job
site.
The soil conditions are not
as expected.
Re-evaluate thawing plan
based on job site condi-
tions.
Pump will not start.
There is no power.
Verify that the breaker
switch is ON. Verify that the
HTF level is within range
and low level cutoff control
is reset (low level indicator
light must be OFF).
The HTF temperature is
below -26°C (-15°F).
Warm the HTF and hoses
before starting machine;
see topic
Preheating the
Heat Transfer Fluid (HTF)
in
this manual.
Hose rewind does not work.
The hose reel brake is not
fully released.
Fully release the hose reel
brake.
The motor temperature is
below nominal value
(<18°C (0°F)).
Warm the enclosure by run-
ning the machine with all
doors closed
or
warm the
enclosure using an exter-
nal heat source.
The foot pedal switch has
failed.
Replace the foot pedal
switch.
Pump is noisy and HTF flow
is below nominal value.
The suction valve is not fully
open.
Verify that the suction valve
is fully open.
The HTF temperature is
below -26°C (-15°F).
Warm the HTF and hoses
before starting machine;
see topic
Preheating the
HTF
in this manual.
The strainer basket is
clogged.
Clean the strainer basket;
see topic
Cleaning the HTF
Strainer
.
Problem / Symptom
Reason
Remedy
Summary of Contents for 5000620172
Page 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes ...
Page 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588 ...
Page 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance ...
Page 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706 ...
Page 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller ...
Page 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller ...
Page 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit ...
Page 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662 ...
Page 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit ...
Page 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram ...
Page 160: ......
Page 161: ......